User guide

DOEPFER
DOEPFERDOEPFER
DOEPFER System A-100 Universal Vactrol Module A-101-9
4
3. Overview
Fig. 3: front panel
Controls:
1 CV: polarizer for CV input
2 Man.: manual vactrol resistance control
3 VAC control: LED display
In- / Outputs:
! CV In: control voltage input
"a VAC1: vactrol 1 connector
"b VAC2: vactrol 2 connector
Remark 1: The front panel scale of the CV input control
1
is
wrong for the first series of modules. This control is a
polarizer not a simple attenuator as shown on the front
panel. The attenuator has been replaced by a polarizer after
the front panels of the first series have already been printed.
Remark 2: In contrast to other A-100 sockets the VCA1/2
sockets
"
""
"
a/b are not grounded, i.e. the two terminals of the
vactrol are connected to the two terminals of the socket in
question.