Specifications
5.8
Electrical System
To install the clearance lamps, DCMC and DCV
recommend only the following parts released by DCAG:
5.8 Connection of the Third
Brake Lamp
The third brake lamp must be connected to the end
connector J8 by a cable 1.5mm
2
, bk/rd. The end
connector is situated in the engine compartment and must
be waterproof.
The connection to the ground is reali
zed by a cable
1.5mm
2
, bn to the ground connection W6 (see wiring
diagram):
Connection of the third brake lamp
End connector A 001 546 87 41
Relay A002 542 14 19
Socket A006 545 07 28
Plug housing, 1-pole A 002 545 10 28
Plug socket housing, 1-pole A 002 545 10 28
Fixing parts A 002 545 10 28
Fuse N 072581 000304
W6
J8
third
brake
lamp
E12
1.5bn
1.5bk/rd
.1
.2
N82.25-2049-00