Specifications
2.2
Body Installation
2.5 Body Mounting Methods
2.5.1 Bolted Connections
If the factory installed bolts have to be replaced with
longer bolts, use only bolts with
– the same diameter
– the same strength class and
– the same thread pitch.
2.5.2 Welded Connections
2.6 Shelf support
Floor attachment
To avoid damage to the floor, the base plates of the shelf
support struts (in front of the sidewalls) must be at least
120 mm wide and 3 mm thick. The y = 750 mm-line as
well as the connection of the inner side wall assembly
must be covered.
A 3 mm thick plate has to be inserted, which fits between
the y = 750 mm-line and the vertical walls of the outer
longitudinal stringer. Round off the edges of this plate to
allow a proper fit of parts.
Roof attachment
Use the vertical flange of the roof framework as the upper
attachment points for the shelf support struts. The
clamped length of the upper clamping connection must be
at least 100 mm. Make sure that the outer clamping jaw
does not clamp the upper crimped over edge of the flange.
Roof
Spacing between the C-column-stick and a connector
element should be at least 50 mm.
Do not perform any welding work on assemblies,
including but not limited to the engine, the
transmission, the axles
and the chassis frame.