Specifications
Other Additional Information
13.11
13.8.2 Welding Work
When welding with electrical equipment, the following
guide lines have to be observed:
– Only trained personal may perform welding on the
chassis frame.
– The positive and negative terminals of the battery
cover have to be disconnected.
– The ground clamp for an arc welder may only be
connected directly to the part which is welded.
Note:
Avoid any contact of the arc welder ground clamp
with any of the drive train assemblies, including but not
limited to engine, transmission, and axles!
– Do not touch electronic component housings,
such as
airbag control modules or electric lines, with welding
electrodes or ground contact clamps for arc welders.
– On cabs with insulating mountings, connect the
welding equipment’s earth terminal to the cab.