Specifications

47
SET-UP PROCEDURES FOR DUSTS AND GRANULES
Start this procedure with the assumption that the unit is in
the mist spray configuration.
 3. a. Disconnect and remove the air pressurization line
that runs from the top of the blower to the base of
the pesticide tank. Plug the openings with the
attached stoppers.
 b. Disconnect and remove the entire outer pesticide
feed line and the nozzle.
 c. Remove the pesticide tank cover and ensure that
the inside of the tank is clean and dry.
 d. Disconnect and remove the pesticide feed line
from inside of the tank and plug the pesticide line
exit hole with the stopper provided.
 e. Using the tools provided, remove the pesticide
tank by loosening the two plastic nuts located
outside and underneath the tank.
 f. Simultaneously pull the nuts outward and lift the
tank away.
 g. Remove the solid metal plate from the base of
the unit.
 h. Ensure that the dust volume control lever, located
on the bottom left side of the frame and inside of
the throttle control lever, is off (all the way down).