Specifications

124
 9. Add liquid to the insecticide tank. Use the 5-gallon
polyethylene plastic tank strapped down behind the
spray head assembly. Use EPA approved ULV
concentrates only. Cautionary Note: No insecticide
spraying should be performed until the pump has
been calibrated.
CALIBRATION PROCEDURES
 10. Disconnect the insecticide tube at the spray head,
just below the blower housing, and place the tube
into an empty container.
 11. Slightly loosen the two knurled knob lock nuts that
secure the pump's pointer, located next to the
electrical box.
 12. Set the pointer at an arbitrary number of 0-10 in the
direction of flow, by rotating the black knob, located
next to the pump numbers.
 13. Turn on the main breaker located on the outside of
the electrical box on the left side. Also turn on the
pump circuit breaker located inside the box.
 14. Depress and hold down the calibration button inside
the electrical box until the insecticide flows without
air bubbles in the line. Release the button and hold
the tube up.
 15. a. Hold the open end of the insecticide tube above
the graduated cylinder.