Contour Enabled: if contour enabled is enabled, the contour feature points of the template
are displayed. If it is disabled, the feature points are not displayed, and only the matching frame is
displayed, which can reduce operation time.
Results Display
You can set several judgment conditions of the results in Results Display.
Quantity Judgment: After opening, you can set the quantity range of matching results. If
the number of matching results is within the quantity range, the module is OK; and if it is not within
the quantity range, the module is NG.
Angle Judgment: After opening, you can set the angle range of matching results, and the
range is -180 ° to 180 ° by default. If the angle of output results is within the quantity range, the
module is OK; and if it is not within the angle range, the module is NG.
X Scale Judgment: in the output results, if X scale is within the range, the module is OK,
otherwise the module is NG.
Y Scale Judgment: it is the same as X Scale Judgment.
Score: it is similar score and means the degree of similarity degree of template and image
detected.
Matching Point X/Y Judgment, Center Point X/Y Judgment: X coordinate of matching
point.
Text Display: Text content, color, font size and location displayed can be edited.
Output Results: you can refer to the Feature Matching.
Circle Search
The tool of circle search detects multiple edge points first, and then fits them into a circle. This tool
is used for location and measurement of circles. The basic parameters and result display have been
explained in Tool Application. This section mainly describes the running parameters.
Running Parameters
Sector Radius: it means the radius of inner and outer circle of the ring ROI.
Edge Type: