Manual

Table Of Contents
DobotVisionStudio User Guide
Issue V4.1.2 (2022-06-08) User Guide Copyright © Yuejiang Technology Co., Ltd.
31
Gain
You can increase gain to improve brightness without increasing exposure time.
Gamma
The camera supports Gamma correction, which provides a non-linear output mapping
mechanism.
Gamma value between 0 and 1: When image brightness increases, dark area becomes
brighter.
Gamma value between 1 and 4: When image brightness decreases, dark area becomes
darker.
Line Rate
It refers to the line rate of line scan camera.
Trigger Settings
Trigger Source
Software trigger means that DobotVisionStudio triggers the camera. Hardware trigger
means using external hardware to trigger the camera.
Trigger Delay
After the configured trigger delay time, the program starts to respond.
IO Control
IO Option
It selects IO port.
IO Mode
It includes input and strobe.
Smart Camera IO Control
IO Selector
Select IO output port.
IO Source
It includes off and software triggering. Off means that output is disabled.
IO Inverter
After you enable it, the electrical signal level will be reversed.
Output Delay
Set the delay time of output, and its unit is us.
Duration
It refers to the duration of IO signals
Smart Camera Light Control
Lighting Enable
After you enable it, the light source will be opened.
Lighting Mode
It includes strobe and constant.
Lighting Duration
It refers to the duration of the strobe.
Lighting Delay
It refers to the delay time of light output.
Lighting Precharge
It refers to the precharge time of light trigger.
Controller Management
You can set the light source and IO devices, as shown below.
Click to add a device. You can select the added device and right-click to rename or delete this
device.