Manual

Table Of Contents
DobotVisionStudio User Guide
Issue V4.1.2 (2022-06-08) User Guide Copyright © Yuejiang Technology Co., Ltd.
229
Filter Kernel Size: For strengthening edge and repressing noise, the minimal value is 1.
Set this value according to the actual needs. If the edge is burry or it is intervened by noises, increase
the value to make the detecting results more stable. However, it might impact the edge position
precision or even cause edge loss, if the interval between edges is less than the filter kernel size.
Edge Pair Model Defect Detection
Edge pair model defect detection is used to compare with the standard model to output relative
defect information, such as width, location deviation, fracture defect and hierarchical defect. You
need to select a relative completed model to execute model building before detecting. Load or train
to generate models in Edge Model. For model building details, see Edge Model Defect Detection.
In model settings, you can click Starting Range, and click Generate Trace to create a trace.