Manual
Table Of Contents
- 1. Updates
- 2. Product Introduction
- 3. Software Interface
- 3.1 Welcome Page
- 3.2 Home Page
- 3.3 Menu
- 3.4 Control Toolbar
- 3.5 Tool Box
- 3.6 Result Display
- 3.7 Flow Management
- 3.8 Camera Management
- 3.9 Controller Management
- 3.10 Global Variables
- 3.11 Communication Management
- 3.12 Global Trigger
- 3.13 Global Script
- 3.14 Operation Interface
- 3.15 Data Queue
- 3.16 Flow Time
- 3.17 Dobot Panel
- 4. Vision Tools
- 4.1 Acquisition
- 4.2 Location
- 4.2.1 Feature Match
- 4.2.2 Greyscale Match
- 4.2.3 Mark Location
- 4.2.4 Circle Search
- 4.2.5 Line Search
- 4.2.6 Blob Analysis
- 4.2.7 Caliper
- 4.2.8 Edge Search
- 4.2.9 Position Correction
- 4.2.10 Rect Search
- 4.2.11 Peak Search
- 4.2.12 Edge Intersection
- 4.2.13 Parallel Lines Search
- 4.2.14 Quadrilateral Search
- 4.2.15 Line Group Search
- 4.2.16 Multi-line Search
- 4.2.17 Blob Label Analysis
- 4.2.18 Path Extraction
- 4.2.19 Find Angle Bisector
- 4.2.20 Find Median Line
- 4.2.21 Calculate Parallel Lines
- 4.2.22 Find Vertical Line
- 4.3 Measurement
- 4.4 Image Generation
- 4.5 Recognition
- 4.6 Deep Learning
- 4.7 Calibration
- 4.8 Calculation
- 4.9 Image Processing
- 4.9.1 Image Combination
- 4.9.2 Image Morphology
- 4.9.3 Image Binarization
- 4.9.4 Image Filter
- 4.9.5 Image Enhancement
- 4.9.6 Image Computing
- 4.9.7 Distortion Correction
- 4.9.8 Image Clarity
- 4.9.9 Image Fixture
- 4.9.10 Shade Correction
- 4.9.11 Affine Transformation
- 4.9.12 Ring Expansion
- 4.9.13 Copy and Fill
- 4.9.14 Frame Mean
- 4.9.15 Image Normalization
- 4.9.16 Image Correction
- 4.9.17 Geometric Transformation
- 4.9.18 Image Stitch
- 4.9.19 Multiple Images Fusion
- 4.10 Color Processing
- 4.11 Defect Detection
- 4.11.1 OCV
- 4.11.2 Arc Edge Defect Detection
- 4.11.3 Linear Edge Defect Detection
- 4.11.4 Arc-Pair Defect Detection
- 4.11.5 Line-Pair Defect Detection
- 4.11.6 Edge Group Defect Detection
- 4.11.7 Edge Pair Group Defect Detection
- 4.11.8 Edge Model Defect Detection
- 4.11.9 Edge Pair Model Defect Detection
- 4.11.10 Defect Contrast
- 4.12 Logic Tools
- 4.13 Communication
- 4.14 Dobot Magician Tools
- 5. Cases
- 6. Dobot Magician Demo
DobotVisionStudio User Guide
Issue V4.1.2 (2022-06-08) User Guide Copyright © Yuejiang Technology Co., Ltd.
173
• Matrix Correction Enable: In the conversion relationship generated by N image
calibration, only when moving the calibration horizontally, the coordinates of the upper left corner
of the checkerboard corner of the first image in the image are the image origin by default. When
there is rotation calibration, the default is that the image rotation center is the origin of the physical
coordinate system. If this correspondence does not meet the requirements, the matrix correction
enable can be enabled.
• Input Mode: it includes by point and by coordinate.
• Image Point: enable matrix correction, input image points, correct the position of the
matrix, and transform this image point into a specified physical point.
• Physical Point: enable matrix correction, input physical points, correct the position of the
matrix, and transform specific image point into the physical point.
Running Parameters:
• Camera Movement: If the camera has relative movement, you can enable this parameter.
• Calibration Board Type: Self-developed I type, and self-developed II type. Type I is a
self-developed code occupying four checkerboard positions, and type II is a self-developed code
placed in the white grid of the calibration board.
• Grayscale Contrast: it refers to the min. value of contrast between adjacent black-and-
white squares in a checkerboard image, it is recommended to use default value.
• Median Filter Status: Whether to perform median filtering before corner point extraction.
There are two modes: "Perform Filtering" and "No Filtering". It is recommended to use the default
value.
• Subpixel Window: 2 modes: self-adaptive, and configured value.
Output Results:
• Average Error of Pixel Translation: according to the pixel estimation error when
translation image calculates the matrix, the smaller the error, the more stable the movement of the
mechanism and the more reliable the calibration result.