Manual

Table Of Contents
DobotVisionStudio User Guide
Issue V4.1.2 (2022-06-08) User Guide Copyright © Yuejiang Technology Co., Ltd.
171
Current Angle Point Quantity
Input the number of corner points extracted in image 1.
Target Angle Point Quantity:
Input the number of corner points extracted in image 2.
Mapping Angle Point
Quantity
The number of corner points extracted from image 1 that can be mapped to
image 2.
N-Image Calibration
N-image calibration tends to create image points and physical points, and calculate the mapping
relationship between the image coordinate system and the physical coordinate system.
Generally, the camera is installed above the self-developed calibration board. Make sure the camera
can capture enough angle points and self-developed codes. The min. value for image translation is
3. When the value is larger than or equal to 4, the direction of movement is changed every 3 images.
At present, translation calibration, rotation calibration and translation rotation calibration can be
supported, as shown in the figure below.
When translating coordinates only, the original point of the physical coordinate system is the start
point of the first calibration board. When rotating coordinates, the original point of the physical
coordinate system is the physical point of the rotation center of the image.