Manual

Table Of Contents
DobotVisionStudio User Guide
Issue V4.1.2 (2022-06-08) User Guide Copyright © Yuejiang Technology Co., Ltd.
115
The image selected when you configure the template should be consistent with the image selected
when you create the feature matching template. Use and to draw the polyline and arc
path to be extracted. Click to generate model, and finally click OK to complete the template.
NOTE
You can draw multiple paths and set their corresponding parameters according to
actual demands. You can also change the order of the paths.
Training Parameter
Number of Path Points: The number of path points on the extracted path in the template,
ranging from 2 to 300, can be selected according to the demand.
Position Offset: The offset of path points can be set according to the actual demand,
ranging from -1000 to 1000.
Edge Polarity: it has three polarities, including dark to light, light to dark and any.
- From Dark to Light: The edge of a region that transitions from a low gray
value to a high gray value.
- From Light to Dark: The edge of a region that transitions from a high gray
value to a low gray value.
- Any: Both edges above can be detected.
Edge Threshold: The edge threshold is the gradient threshold, ranging from 0 to 255. Only
edge points whose edge gradient threshold is greater than this value are detected. The larger