    Dobot M1 User Guide  6 Operation 
Issue V1.0.4 (2018-08-30)  User Guide  Copyright © Yuejiang Technology Co., Ltd 
  63   
Table 6.5 Parameter Description of the saved point 
Parameter 
Description 
Type 
The command type of Dobot M1 
Value: 
  JUMP 
  MOVJ 
  MOVL 
  ARC 
  CIRCLE:  The  method  to  save  points  in  CIRCLE  mode  is  the 
same as that of ARC mode. For details, please see 6.1.3 Saving 
Point in ARC Mode 
  TRIGGER 
  OUTPUT 
  WAIT 
Name 
The name of the current saved point, which is user-defined 
Content 
The  contents  displayed  depends  on  Type.  You  can  double-click  contents 
displayed in Content to modify them. 
  MOVL/MOVJ/JUMP/ARC/CIRCLE:  Indicates  the  coordinate  values, 
the  velocity  ratio  and  the  jerk  ratio  of  the  movement  when 
implementing playback. 
If  Type  of  the  current  saved  point  is  MOVL,  ARC,  or  CIRCLE, 
Armorientaion must be the same as that of the previous saved point.   
In MOVL mode, if you modify the arm orientation of the current saved 
point, an alarm will be generated. 
  Trigger: Input of I/O interface 
  Output: Output of I/O interface 
  Wait: The pause time of the previous saved point 
  Select a  saved  point  and  right-click on  the  line  to  copy,  delete  or  other operations,  as 