SDS
新 利 達 電 池 實 業 有 限 公 司
NEW LEADER BATTERY INDUSTRY LTD.
香港九龍觀塘開源道 62 號駱駝漆大廈第一期四樓 A 座
FLAT A, 4/F., Blk 1, CAMELPAINT BLDG., 62 HOI YUEN ROAD, KWUN TONG, KOWLOON HONG KONG
TEL:(852) 2790 6280 FAX:(852) 2763 4104 Website:www.newleader.com.hk E-mail: sales@newleader.com.hk
Material Safety Data Sheet for LR44 Alkaline Button cell
Document Number: Revision: 00 Page 2 of 4
Section V – Reactivity Data
Stability Unstable
Conditions to Avoid Stable
Incompatibility (Materials to Avoid)
Hazardous Decomposition or Byproducts
When heated, battery may emit hazardous vapour of KOH/NaOH and Hg Hazardous (Regular type)
Polymerization May Occur Conditions to Avoid
Will Not Occur
Section VI - Health Hazard Data
Route(s) of Entry
Inhalation
N.A.
Skin
N.A.
Ingestion
N.A.
Health Hazard (Acute and Chronic) / Toxicological information
In case of electrolyte leakage, skin will be itchy when contaminated with electrolyte.
In contact with electrolyte can cause severe irritation and chemical burns.
Inhalation of electrolyte vapors may cause irritation of the upper respiratory tract and lungs.
Section VII – First Aid Measures
First Aid Procedures
If electrolyte leakage occurs and makes contact with skin, wash with plenty of water immediately.
If electrolyte comes into contact with eyes, wash with copious amounts of water for fifteen (15)
minutes, and contact a physician.
If electrolyte vapors are inhaled, provide fresh air and seek medical attention if respiratory irritation
develops. Ventilate the contaminated area.
Section VIII - Fire and Explosion Hazard Data
Flash Point (Method Used)
N.A.
Ignition Temp.
N.A.
Flammable Limits
N.A.
LEL
N.A.
UEL
N.A.
Extinguishing Media
Carbon Dioxide, Dry Chemical or Foam extinguishers
Special Fire Fighting Procedures
N.A.
Unusual Fire and Explosion Hazards
Do not dispose of battery in fire - may explode.
Do not short-circuit battery - may cause burns.