User Manual
6
3. Place a good quality, 10 inch (254.0 mm) master
square on the worktable against the post's back side.
Measure clearance between the post and square
near the bottom of the post. Clearance should be
within 0.007-inch ±0.005-inch (0.18 mm ±0.13 mm)
at the bottom of the post for standard machines.
4. Add or remove shims under the base pads until the
correct post to square clearance is obtained.
Themachinemustbeboltedtotheoorfor
worktable loads over 100 pounds (45.4 kg).
ELECTRICAL INSTALLATION
Electrical installation must be made by
authorized electrical maintenance personnel
only!
1. Refer to the machine specications plate on the
machine frame to verify that the electrical supply
circuit will meet the voltage/phase/frequency/
amperage requirements listed. A basic data plate
is reproduced on this manual’s introductory page.
2. Bring the incoming power leads into the machine's
electrical box. Refer to the electrical schematic, if
necessary, when making the connections.
3. Turn the disconnect switch on the electrical box to
ON. Then: (a) Alternately jog the Hydraulic Start
/Stop pushbutton; (b) Check to make sure the saw
band is running in a clockwise motion; (c) Reverse
the leads if hydraulic pump rotation is incorrect.
4. If the machine has provided overload protection,
the overload relay may kickout when starting and
stopping numerous times in rapid succession. If
this happens, let the relay cool for a few minutes
before restarting the machine.
PLANT AIR INSTALLATION
1. Shop air is required to operate the standard mist
coolant and the optional band mist lubricator.
Incoming air supply should be between 80 and 90
psi (5.5 and 6.2 bar or 5.6 and 6.3 kg/cm²).
DO NOT exceed 90 psi (6.2 bar or 6.3 kg/
cm²).
PREPARATION FOR USE
1. Check the transmission oil level. Capacity is
approximately 1.7 pints (0.80 liters). If the reservoir
level is low (or empty): (a) Check to see that the
transmission plug is installed tightly; (b) See the
"Maintenance" section for proper procedure of
checking and/or lling the transmission. (c) Refer
to the Lubrication Chart later in this manual for
recommended lubricants.
2. Check the mist coolant bottle located on the upper
rear side of the saw head for the proper reservoir
level. Capacity is one (1) quart (0.95 liter). Refer to
the Lubrication Chart for recommended lubricant.
3. Be sure the hydraulic reservoir is full. Capacity is
approximately three (3) gallons (11.3 liters). On top
of the reservoir, remove the pipe plug and install the
breather. The breather can be found in the box of
extra parts shipped with the machine.
4. Make sure all other points listed by the Lubrication
Chart have been properly checked and/or
serviced.
MACHINE ALIGNMENT (Continued....)