User Manual
DMXking.com • JPK Systems Limited • New Zealand
0106-700-1.1
5
Port Tab A (DMX512 port)
Parameter
Default Setting
Network Mode
Static IP address
Operation Mode
DMX Out
Fixed IP
0.0.0.0 [Only for DMX IN – Unicast to 1 IP address only]
DMX Universe
1 [Net 00, Subnet 0, Universe 0]. Note sACN Universe 1 = Art-Net 00:0:0
Merge Mode/Timeout all sources
HTP, Timeout un checked
DMX512 Update Rate
40 [DMX512 frames per second]. Universe Sync will override.
RDM Packet Spacing
1/20s
RDM Discovery Period
0s [RDM Disabled]
Broadcast Threshold
10 [Art-Net II/3/4 unicasting up to 10 nodes]. Set to 0 for Art-Net I broadcast
on DMX IN ports.
Recall DMX Snapshot at startup
Recall unchecked
4. CONFIGURATION UTILITY
The eDMX Configuration utility provides a simple interface to all device parameters. Only version 1.12 and above is compatible
with LeDMX4 PRO devices. Typically these are set once during initial configuration and left untouched. If you are not confident in
setting up network IP Address, Subnet Mask and Default Gateway parameters please get in touch with DMXking.com support and
we’ll walk you through the process. DHCP is supported from firmware v2.6 onwards.
Special note: Once you’ve finished configuring your eDMX product close the application before starting your lighting control
application if it’s running from the same computer. In general only 1 Art-Net application will function at a time.