Installation Instructions

Planning the Job
3
DMX AG Foundation Guide: Version 4.3
Updated: September 9, 2014 (clarifications only denoted by )
Supplies Required
Rolls of DMX AG
1 roll for every 65 feet (20 meters) of foundation
perimeter.
Choose the height that matches the distance
from the footing to the grade line.
DMX AG comes in a variety of heights up to 8
feet (2.4 meters). If you need more height or if
you have to piece the DMX AG™, you can
overlap the top layer over the bottom layer by at
least 6 inches (15 cm) and mesh the dimples.
DMX FlexTrim
For sealing cut edges in the membrane where
the flat panel has had to be trimmed off, such as
around windows or on a slope. The DMX
FlexTrim prevents dirt from getting between
the membrane and the wall. Can also be used
for additional protection, over the finished flat tab.
DMX Washers
For use with nails or screws on both the flat tab
and dimpled section of membrane.
DMX approves the use of washers as follows:
Flat Tab on Membrane: Plastic Washers or
FlexTrim*
Dimpled Section of Membrane: Plastic
Washers or Steel Washers with a rubber
insert to protect damage to the sheet.
Approximately 80 DMX Quick Clips* or
Approximately 150 to 200 Washers per roll of
DMX AG™.
1 ¼ inch concrete nails
(for poured or concrete
block foundations)
OR
1 ½ inch deck or
drywall screws (for ICF
& PWF foundations)
For fastening the flat tab at the top of the DMX
AG to the foundation. Use one nail or screw
with a washer every 6 to 8 inches* (15 to 20 cm).
For fastening DMX Washers into the dimples.
For fastening DMX FlexTrim.