Windows
For windows or other openings in the foundation, cut the membrane 2 to 4 inches
(5 to 10 cm) back from the edge. Fasten the membrane to the foundation wall
under the opening using DMX Washers as usual. Since you have trimmed off
the flat tab, you must install DMX FlexTrim to seal the cut edges to within 3"
(7.5 cm)* of the opening.
3"
Cut the membrane back
from the edge of openings
in the foundation, 4” min*.
Sealant at DMX FlexTrim Interface* when
installed for Wall Waterproofing