SERIAL COMMUNICATION PROTOCOL
SERIAL COMMUNICATION PROTOCOL
Command Description Response
CON:a,b,c,||d,e,f,g Congure ON Buttons ACK:
A = Channel number.
1 = Ch 1
2 = selects Ch 2
etc
a = selects Ch 10
B = Input 1 ON Control
1 = on
0 = o
C = Input 2 ON Control
1 = on
0 = o
D = Mode for Input 1
0 = ON / OFF
1 = ON / REPEAT / OFF
E = Mode for Input 2
0 = ON / OFF
1 = ON / REPEAT / OFF
F = Lock Button
0 = Normal Operation
1 = Button Locked
G = Force Fader Up
1 = Fader Forced Up
0 = Normal Operation
N.B. if button is forced on,(F=1) the B / C = Button Control has no
eect.
N.B If Telco mode on Input 1 is enabled, option D shall be forced
to 0 = ON / OFF
N.B If Telco mode on Input 2 is enabled, option E shall be forced
to 0 = ON / OFF
CON:a? Read ON Button Status CON:a,b,c,d,e,f,g,h,i
A = Channel number. (see above)
H = Fader Position
0 = Fader Down
1 = Fader Up
I = Channel Routed
0 = Not Routed
1 = Routed