User's Manual

DIGITAL-LOGIC AG MSM855/HLV/B/B2 Detailed Manual V1.0A
101
10. THERMAL SPECIFICATIONS
10.1. Thermal Analysis for Case Integration
Since the integrated heat sink is uni-directional, the airflow must be exactly in the direction of the heat rails. If
possible, mount the board vertically, so that the heat rails are up/down. In this case, the self produced airflow
is about 3m/sec.
Pay particular attention when mounting the PC-product in a fully enclosed case/box. The thermal energy will
be stored in the inner room of this environment.
If the case has a fan:
The hot air must be exchanged with cool air from outside using a filtered fan.
The hot air must be cooled with a heat exchanger.
If the case has no fan or opening to exchange the hot air:
The heat sink of the CPU must be mounted directly to a heat sink integrated in the case. The thermal
energy does not go through the air; the heat will be conducted directly through the alloy of the heat
sink to the outside.
Diminish the thermal energy production by reducing the CPU performance, i.e. by using the 600MHz
clock only.