Installation Guide

AIMS Fast-Scan Radar v3.22 Installation and Operations Manual
DMT, LLC • DMT-M200-311 • 08/2009
29
Gain. The gain control value changes the amount of energy radiated by increasing the
pulse width in nanoseconds.
Also displayed in the area are;
SeaIOCardID.
Num
Handle
These values are returned by the radar’s digital I/O board on initialization. If the values
displayed in these boxes are not simple integers, the A/D board may not be properly setup
(consult DMT for technical assistance).
4.2.2.2 Radar Settings
The radar settings include;
Range Bins. Defines the total number of range bins to be processed (including zero range
gate) on each dwell.
Pulses. Defines the number of pulses to be transmitted on each dwell.
Zero Range Gate. The “zero range gate” defines the internal delay (in ‘bins’) before the
transmitted pulse actually leaves the antenna. This is a factory-set parameter and should
not be changed. This value is normally set between 15 and 20.
XMIT Frequency. This entry is set to the center frequency configuration of the system so
the graphing function correctly displays the Doppler information (use Change XMIT
Freq to set). Note: It is important that this number is properly set. It is used in the
calculation of the detected speed of an intruder.