• Gain. The gain control value changes the amount of energy radiated by increasing the
pulse width in nanoseconds.
Also displayed in the area are;
• SeaIOCardID.
• Num
• Handle
These values are returned by the radar’s digital I/O board on initialization. If the values
displayed in these boxes are not simple integers, the A/D board may not be properly setup
(consult DMT for technical assistance).
4.2.2.2 Radar Settings
The radar settings include;
• Range Bins. Defines the total number of range bins to be processed (including zero range
gate) on each dwell.
• Pulses. Defines the number of pulses to be transmitted on each dwell.
• Zero Range Gate. The “zero range gate” defines the internal delay (in ‘bins’) before the
transmitted pulse actually leaves the antenna. This is a factory-set parameter and should
not be changed. This value is normally set between 15 and 20.
• XMIT Frequency. This entry is set to the center frequency configuration of the system so
the graphing function correctly displays the Doppler information (use Change XMIT
Freq to set). Note: It is important that this number is properly set. It is used in the
calculation of the detected speed of an intruder.