Installation Guide
1102 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
5
TEST THE TRANSMITTER
After the transmitterhas been installed, test to confirm that it is communicating reliably with the panel. Use
the Tech APP™ to perform a Wireless Walk Test on the system or complete the following steps to perform a
Walk Test from a keypad that is connected to the panel:
At the keypad, enter 8144 (WALK) and select WLS. If the transmitter fails to check in at the keypad,
ensure that it is wired properly and check for sources of interference such as metal objects and electronic
equipment.
ADDITIONAL INFORMATION
Supervision Time
When a receiver is installed, powered up, or the panel is reset, the supervision time for transmitters is reset. If the
receiver has been powered down for more than one hour, wireless transmitters may take up to an additional hour to send
a supervision message unless tripped, tampered, or powered up. This operation extends battery life for transmitters. A
missing message may display on the keypad until the transmitter sends a supervision message.
Replace the Battery
1. Push the button on the end of the transmitterand separate the two halves.
2. Remove the old battery, observe polarity, and place the new battery in the holder.
3. Snap the cover back on the transmitter.
Sensor Reset to Clear LOBAT
Once the battery is replaced, a sensor reset is required at the keypad to clear the LOBAT message. On an LCD keypad,
press and hold 2for two seconds. On a graphic touchscreen keypad, press RESET. Enter your user code, if required. The
keypad displays SENSORS OFF followed by SENSORS ON.