User Guide
XR500 Series Canadian Programming Guide Digital Monitoring Products
21
deviCe SeTuP
6.15.9
REQUIRE SITE
CODE? NO YES
Require Site Code
Press the top row Select key under YES to use a site code.
InadditiontoUserCodeverication,dooraccessisonlygrantedwhenanyonesite
codeprogrammedattheSITECODEENTRYoptionmatchesthesitecodereceivedin
theWiegandstring.
6.15.9 .1
SITE CODE 1: -
Site Code Display
Youcanprogramuptoeightthree-digitsitecodes.Sitecoderangeis0-999.
Any previously programmed site codes display. Dashes represent blank site
codes.
SiteCode1displaysrst.Enterathree-digitsitecodenumberfollowedby
the command key to advance to the next prompt, Site Code 2. To delete
an existing site code, press any select key. Either enter a new site code
followed by command, or press command to leave blank and continue to the
nextsitecode.Repeatthesestepstochange,delete,oraddupto8site
codes.
Note: A card with a site code greater than three digits cannot be used.
Use only cards with three-digit site codes.
6.15.10
NO OF USER CODE
DIGITS: 5
Number of User Code Digits
The734modulerecognizesusercodesfromfourtotendigitsinlength.Pressany
toprowSelectkeytoenterausercodedigitlengthbetween4-10digits.This
number must match the user code number length being used by the panel. Default
is5.ForanXR500AreaSystem,use4to10digits(typically5).Forallothersystems
and panels, use 4 digits.
Anyselectionabove5digitsrequireentryofthecustomcarddenitionswithcustom
siteandusercodepositionsfortheWiegandstring.Whensearchingthebitstring
fortheusercode,thedigitsareidentiedandreadfromlefttoright.
6.15.11 Degraded Mode
Thisoptiondenestherelayactionwhencommunicationwiththepanelhasnot
occurredforveseconds.PressanytoprowSelectkeytodisplayrelayaction
options.PresstheBackArrowkeytoreturntotheNOOFUSERCODEDIGITS:.
Choose the Degraded Mode Action required.
PresstherstSelectkeytochooseOFF[Default] (RelayAlwaysOff) — The relay
doesnotturnonwhenanyWiegandstringisreceived.OffdoesnotaffectanyREX
operation.
PressthesecondSelectkeytochooseSITE(AcceptSiteCode) — Door access
isgrantedwhentheWiegandsitecodestringreceivedmatchesanysitecode
programmedatSITECODEENTRY.FordetailsreferbacktotheREQUIRESITECODE
option.
PressthethirdSelectkeytochooseANY(AnyWiegandRead) — Door access is
granted when any Wiegandstringisreceived.
Press the fourth Select key to chooseON(RelayAlwaysOn)—Therelayisalwayson.
PresstheCOMMAND key to display the next action.
PresstherstSelectkeytochooseLAST(KeepLastState) — The relay remains in the
same state and does not change when communication is lost.
Afterchoosingtheaction,theDEGRADEDMODEoptionandthenewlydenedaction
display.
Programmingisnowcomplete.PresstheCOMMANDkeytodisplayDEVICENO.Press
the Back Arrow toreturntotheNOOFUSERCODEDIGITSoption.
DEGRADED MODE:
RELAY ALWAYS OFF
DEGRADED MODE:
ACCEPT SITE CODE
DEGRADED MODE:
ANY WIEGAND READ
DEGRADED MODE:
RELAY ALWAYS ON
DEGRADED MODE:
OFF SITE ANY ON
DEGRADED MODE:
PRESERVE LAST
DEGRADED MODE:
LAST