Programming Guide XR500 Series CANADIAN Command Processor™ Panel
MODEL XR500 SERIES CANADIAN ACCESS CONTROL COMMAND PROCESSOR™ PANEL PROGRAMMING GUIDE Contains programming Instructions for use with the Model XR500, XR500N, XR500E Canadian Access Control Command Processor™ Panels. When using the XR500 Series Canadian panel for any ULC other listing organization’s approved methods, refer to this manual and the XR500 Series Canadian Installation Guide (LT-0681CAN).
Table Of Contents 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.14 Before you Begin.................................................................. 1 Programming Information Sheet............................................ 1 Getting Started..................................................................... 1 Encrypted Communications (XR500N/XR500E only)................. 2 Programmer Operation.......................................................... 2 Programmer Lockout Codes..............
Table of Contents 4.3 4.4 4.5 4.6 Gateway Address.................................................................13 Subnet Mask.......................................................................13 DNS Server.........................................................................13 Passphrase (XR500E only)....................................................13 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15 5.16 5.17 5.18 Messaging Setup..............................................
Table Of Contents 7.5.2 7.6 7.6.1 7.6.2 7.7 7.8 7.8.1 7.8.2 7.8.3 7.8.4 7.8.5 7.8.6 7.8.7 7.9 7.9.1 7.9.2 7.9.3 Encrypt Network Remote......................................................23 Allow Cellular Remote..........................................................23 First GPRS APN / Second GPRS APN......................................23 Encrypt Cellular Remote.......................................................23 Allow RS-232 Remote...........................................................
Table of Contents Output Options................................................................33 11.1 11.2.1 11.2.2 11.3 11.4 11.5 11.6 11.7 11.8 11.9 11.10 11.11 11.12 11.13 11.14 11.15 11.16 Output Options....................................................................33 Cutoff Output .....................................................................33 Output Cutoff Time..............................................................33 Communication Trouble Output..................................
Table Of Contents 17.9 17.10 17.11 17.12 User Command Reports.......................................................42 Door Access Reports............................................................43 Supervisory Reports.............................................................43 PC Log Real-Time Status......................................................43 18.1 18.2 18.3 18.4 18.5 18.6 18.7 18.8 18.9 18.10 18.10.1 18.10.2 18.11 18.12 18.13 18.14 18.15 18.16 18.17 18.18 18.19 18.20 18.21 18.
Table of Contents 19.13 19.14 19.15 19.16 19.17 19.18 19.19 19.20 19.21 19.22 19.23 19.24 19.25 19.26 19.27 19.28 19.28.1 19.29 19.30 Alarm Action.......................................................................56 Disarmed Open ..................................................................56 Report to Transmit...............................................................57 Output Number...................................................................57 Output Action............................
This page intentionally left blank.
Introduction Introduction 1.1 Before you Begin This guide provides programming information for the DMP XR500, XR500N, and XR500E Command Processor™ Panel. After this Introduction, the remaining sections describe the functions of each programming menu item along with the available options. Before starting to program, we recommend that you read through the contents of this guide.
Introduction 1.3 Encrypted Communications (XR500N/XR500E only) Some installations require secure data communications. DMP offers NIST approved AES encrypted communication. Use a unique passphrase to enable encrypted communications and provide a secure means for data communications. See Network Options. An XR500E panel communicates using AES encryption.
Introduction 1.7 Power Up When the XR500 Series Canadian panel is powered up after an AC power failure, any zone transitions are not recognized for 60 seconds. Normal zone processing resumes at the end of the 60 seconds. 1.8 Keypads DMP offers multiple keypads in a variety of styles. All DMP keypads provide the same programming capabilities. Each keypad and its operation are shown and described in the following sections.
Introduction 1.10 Entering Alpha Characters Some options during programming require you to enter alpha characters. To enter an alpha character, press or touch the key that has that letter written below it. The keypad displays the number digit of the key. Next, press the Select key/area that corresponds to the location of the letter under the key. Pressing a different Select key/area changes the letter.
Introduction 1.13 Multiple Displays 1.14 Asterisks in Programming For many programming and user options, such as Area selections, Menu Displays, and Status Lists, there are several displays containing programming. For example, when programming Menu Displays, keypads 1 through 16 display on two separate displays. First, keypads 1 through 8 display. Press the COMMAND key to display keypads 9 through 16. This same scheme is used for areas 1 through 32.
Initialization Initialization NOTE: WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE RUN AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE THE PROGRAMMING CHANGES. SEE SECTION 17.1. 2.1 Initialization Initialization This function allows you to clear selected parts of the panel program back to the factory defaults in preparation for system programming. Run the initialization function on all new installations.
Initialization 2.9 Com/Rmt? NO YES Clear Communication and Remote Options Sure? Yes NO NO - Leaves existing communication and remote options intact. YES - Clears communication and remote options programming to factory defaults. 2.10 Defaults NO YES Set to Factory Defaults Sure? Yes NO NO - Leaves existing panel programming intact. YES - Sets the remainder of the panel programming back to the factory defaults. Note: Sets the Programming and User language to English.
Communication Communication 3.1 3.2 3.3 3.4 3.5 Communication Communication Account No: 12345 Account Number XMit Delay: 30 The Account Number is a 1 to 5 digit number used to identify which panel is sending a message. Enter the account number sent to the SCS-1R Receiver. Messages may be sent to a central station or via PC Log Reports to a PC. The default is 12345. NET, CELL, 232 and DD - The range of valid account numbers for a panel is 1 to 65535.
Communication 3.6 path type: BackUP Path Type priMARY BACKUP The Path Type defines if the path is Primary or Backup. Because Path 1 is Primary, this prompt only displays for paths 2-8. Default is Backup. Note: If the Primary Communication Type is CELL, then the backup Communication Type can only be NET or 232. 3.7 Test RPT: YES Test Report No yes defer 3.8 1 dy Test freq: Test Report determines if test reports are sent on this path.
Communication 3.15 3.16 3.17 3.18 Receiver Port receiver port - 2001 Enter the receiver port number. Valid range is 1 to 65,535. Default is 2001. first phone no. First Telephone Number second phone no. Second Telephone Number advanced? no yes Advanced Programming This option displays only if the Communication Type is DD or CID. This is the first number the panel dials when sending reports to the receiver.
Communication 3.22 Retry Seconds Retry seconds: 6 This option displays for NET or 232 Communication Types. Enter the number of seconds (between 6 and 15) the panel should wait before retrying to send a message to the receiver if an acknowledgment was not received. The panel retries as many times as possible for a period of one minute before sending a network trouble message. For example, if retry time is set to 15, the panel retries four times. The default Retry Time is 6 seconds.
Communication 3.29 Alarm yes no yes fire 3.30 spv/trbl yes no yes fire 3.31 3.32 Supervisory/Trouble Reports This prompt displays when the Path Type is Primary. All backup paths within the group follow the same programming for Supervisory/Trouble Reports. Default is Yes.
Network options Network Options (XR500N/XR500E only) Network Options are provided to define the network configuration for the panel. This information will be used during communication of messages via network or email. Note: IP addresses and port numbers may need to be assigned by the network administrator. When entering an IP, Gateway, or Subnet Mask address be sure to enter all 12 digits and leave out the periods. For example, IP address 192.168.000.250 is entered as 192168000250. 4.
Messaging Setup Messaging Setup 5.1 MESSAGING sETUP Messaging Setup This section allows you to enter the information needed to receive messages directly from the panel via email and In Touch™ SMS Text using Network or Cellular communication. All of the name and password options below allow up to 32 lowercase characters to be entered. The Destination addresses allow up to 48 characters to be entered. System Name is displayed with initial caps.
Messaging setup 5.9 DESTINATION 3 User numBER: 5.10 5.11 5.12 5.13 Destination 3 User Number 0 If Destination 3 is a cellular number, enter the user’s User Number for arming/disarming authorization. EMAIL COMM TYPE Email Communication Type NET CELL Choosing NET sends email messages over the network. Choosing CELL sends email messages via cellular communication. Default is NET.
Device Setup 6.1 6.2 6.3 6.4 Device Setup Device Setup Device Setup This section allows you to define the XR500 Series Canadian panel physical configuration. You can install and address up to sixteen supervised devices on the keypad data bus. Device No:Device 1: dOOr Device Number Door Name 1 Door Name ACCESS AREAS: Access Areas Enter the device number on the keypad bus you are programming. The keypad bus can have up to 16 devices.
Device Setup 6.6 display AREAS: *1 *5 *2 *6 *3 *7 *9 *10 *11 *13 *14 *15 *17 *18 *19 *21 *22 *23 *25 *26 *27 *29 *30 *31 Display Areas *4 Press the COMMAND key to program Display Areas. To select an area between 1 and *8 32, enter the area number using the keypad digit keys. When an area is selected, an asterisk appears next to the area number. Enter the number again to deselect the *12 area. Press COMMAND to display the next set of areas. Default is all area numbers.
Device Setup 6.7 Strike Time: 6.8 STRIKE DELAY: 6.9 Fire Exit 6.10 Out Group NO Yes 6.11 Override NO Yes 6.12 AUTO FORCE ARM Auto Force Arm Device? DEVICE? NO Yes Select YES to have all Display Areas assigned to this keypad automatically arm and force arm faulted zones at arming. The user is not prompted to select areas to arm or force arm faulted zones after choosing ARM at the keypad.
Device Setup 6.15 Program 734 Options? 6.15.1 ACTIVATE ZONE 2 SHUNT? 6.15.2 6.15.3 Program 734 Options Select YES to program the 734 Wiegand Interface Module. Device type must be set to NO Yes DOOR. Activate Zone 2 Shunt NO YES Select YES to activate the Soft-Shunt™ option. Selecting NO allows standard zone operation on Zone 2 and displays the ACTIVATE ZONE 3 REX option. Default setting is NO.
Device Setup 6.15.6 Activate Onboard Speaker ACTIVATE ONBOARD SPEAKER? NO YES Select YES to enable the onboard piezo speaker for local annunciation. Select NO to turn the piezo off for all operations. This does not affect remote annunciator open collector (RA) operation. The default is YES. Press the COMMAND key to display the CARD OPTIONS option. The Back Arrow returns to ACTIVATE ZONE 3 REX. 6.15.7 CARD OPTIONS: Card Options DMP Press any top row Select key to display options.
Device Setup 6.15.9 REQUIRE SITE CODE? NO YES 6.15.9 .1 6.15.10 Require Site Code Press the top row Select key under YES to use a site code. In addition to User Code verification, door access is only granted when any one site code programmed at the SITE CODE ENTRY option matches the site code received in the Wiegand string. Site Code Display SITE CODE 1: - NO OF USER CODE DIGITS: 5 6.15.11 You can program up to eight three-digit site codes. Site code range is 0-999.
remote options Remote Options 7.1 7.2 Remote Options Remote Options This section allows you to enter the information needed for Remote Command/ Remote Programming operation. Remote Key REmOtE Key: This option allows you to enter a code of up to 16 characters. The Remote Link™ program must give the correct key to the panel before being allowed any remote functions. All panels are shipped from the factory with the key preset as blank.
Remote Options 7.4.3 7.4.4 PC MODEM No YES PC Modem ManuFacturer Manufacturer Authorization Auth? No YES 7.5 ALLOW YES allows the panel to answer the telco link and connect with Remote Link through the PC Modem at 2400 baud. NO disables PC Modem communication. Select YES to allow DMP Technical Support technicians to access the panel during system service or troubleshooting. This authorization automatically expires within one hour.
remote options 7.8.4 entre BACKUP IP: Entré Backup IP Address This option displays only if NET is chosen for the Entré connection. Enter the IP backup address where the panel sends network messages if the first Entré IP Address fails. The Entré IP Address must be unique and cannot be duplicated on the network. Enter all 12 digits and leave out the periods. For example, enter IP address 192.168.0.250 as 192168000250. The periods display automatically.
System Reports System Reports 8.1 System Reports System Reports Select specific system reports the panel sends to the receiver. 8.2 Abort No YES Abort Report YES allows the panel to send an alarm abort report to the receiver any time an area is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff Time has not expired. After disarming an area, if any other area remains armed and has zone(s) in alarm, the alarm abort report is not sent.
System Reports 8.8 Ambush No YES Ambush YES allows an ambush report to be sent anytime user code number 1 is entered at a keypad. NO disables the ambush report and allows user number 1 to operate the same as all other codes. 8.9 PANIC TST No YES Panic Test Communication (XR500N/XR500E only) YES allows the panic zone test verification and failure results to be sent to the central station receiver. NO disables the panic test report. The default setting is NO.
System Options System Options 9.1 System Options System Options This section allows you to select system-wide parameters. 9.2 System SYSTEM: area This option allows you to program how the areas operate for arming and disarming. The options you can choose are listed below: AREA - All 32 areas can be programmed and operated independently. AREA A/P H/A GST ALL/PERIMETER - Area 1 is the Perimeter and Area 2 is the Interior.
System Options 9.6 CRS ZONE TM: 4 Cross Zone Time Enter the time allowed between zone faults. When zones are cross zoned, the same zone or a second cross zoned zone must fault within this time in order for an alarm report for both zones to be sent to the receiver. If the cross zone time expires without the second zone faulting, only a zone fault from the first zone is reported. Cross-zone time can be from 4 to 250 seconds. Entering 0 (zero) disables this function. Default is 4. See the Appendix. 9.
System Options GMT 0 1 2 3 4 5 6 7 8 9 10 11 12 9.12 9.
System Options 9.15 9.16 9.17 9.18 For example, when Spanish is selected at a keypad, the User Menu and Status List text display in Spanish at that keypad. When the user later accesses the keypad, pressing the COMMAND key once displays the option for English, Spanish, or French. Pressing the COMMAND key again continues to display the Status List text in Spanish.
System Options 9.19 9.20 9.21 9.22 Wls aUDIBLE: day Wireless Audible Annunciation This option displays when the House Code entered is for a DMP 1100 Series Wireless system (1-50). Press any top row key to select the keypad buzzer annunciation WIRELESS aUDIBLE method for wireless low battery and missing messages. Select ANY to enable aNY dAY mIN annunciation anytime. Select DAY to enable annunciation except during sleeping hours (9 PM to 9 AM).
bell Options Bell Options 10.1 Bell Options This section allows you to program the panel bell output functions. BELL OPTIONS 10.2 Bell Cutoff Time BELL CUTOFF: 15 Enter the maximum time from 1 to 99 minutes the Bell Output remains on. If the area is disarmed, the cutoff time resets. Enter 0 (zero) to provide continuous bell output. The default is 15 minutes. Note: To support the Alarm Verify feature on an All/Perimeter or Home/Sleep/Away system, set the Bell Cutoff Time to greater than 0.
Output Options Output Options 11.1 Output Options output Options This section allows you to program panel output options. The panel provides two Form C relays (1 and 2) and four switched ground (open collector) outputs numbered 3 to 6. Expand the system up to 500 additional relay outputs using J22 LX-Bus on the panel, multiple 716 Output Expander Modules, and up to five interface cards. In addition, 45 wireless outputs are available when using the 1100X wireless receiver.
Output Options 11.6 Panic Alarm Output PANIC ALM out: 0 Enter the output number to turn on when any Panic type zone is placed in an alarm condition. The output is turned off after all Panic zones are restored from an alarm condition and a Sensor Reset is performed. Enter 0 (zero) to disable. Wireless Outputs • The Panic Alarm is compatible with the Model 1118 Wireless Remote Indicator Light and the Model 1116 Wireless Relay Output connected to a Model 572 Indicator LED.
Output Options 11.15 Closing Wait Output CLS WAIT out: 11.16 0 Enter the output number to turn on for approximately four (4) seconds when Closing Wait is programmed as YES and the panel successfully communicates the closing message at arming. If the closing message does not communicate successfully, this output does not turn on. Arm-Alarm Output ARM-ALarm out: 0 Enter the output number to turn on steady when any area of the system is armed.
Output INFORMATION Output Information 12.1 Output Information OUTPUT info 12.2 This section allows you to program wireless outputs and name wired outputs. Output Number Output No. X X X Enter an output number. Entry range is 1 to 6, 450 to 474, 480 to 499, 500 to 999. 12.3 Output Name output name This section allows you to define a 32 character alphanumeric name for any output numbers. The name can display on the keypad when a user performs the browser feature at Outputs On/Off.
Output Groups Output Groups 13.1 Output Groups Output Groups This function allows you to assign outputs to groups. Output groups can be assigned to other areas of programming such as Output Options or Alarm Action of Zone Information, just like single outputs are assigned. This allows the entire group of outputs to turn on and off as required by the programming option. 13.2 Group Number Group No: - Enter a group number from 1 to 20. Up to 20 different groups may be assigned. 13.
Menu Display Menu Display 14.1 Menu Display Menu Display Menu Display allows you to select at which keypad addresses the user can access the following functions. To select a keypad, enter the device number (keypad address) using the digit keys on the keypad. When a keypad is selected, an asterisk appears next to the keypad address. Enter the number again to deselect the keypad. Press the COMMAND key to display the next set of keypads (9 through 16).
Status List Status List 15.1 Status List Status List This function allows you to select the zone alarms and troubles, and system monitor troubles displayed at the keypads. The Status List function operates automatically when the keypad is not performing any other function. The keypad stays in the Status List until the user arms or disarms or selects a menu option. Status List alternates with the Armed Status on keypad addresses selected in the Menu Display - Armed Status section.
Status List 15.5 Burglary Zones: Burglary Zones Specifies the keypad addresses (1 through 16) where all burglary zone alarms and troubles display. Burglary zones include Night, Day, and Exit type zones. Burglary zone troubles remain in the list until the zone restores. All keypads are selected by default. For zone alarms, only the last burglary zone tripped remains in the list.
Printer Reports Printer Reports 16.1 Printer Reports Printer Reports This section allows you to define the operation of a local printer connected to the panel through the use of a DMP 462P Printer Interface Card. The 462P allows you to connect the DMP SCS-PTR or other compatible 40-character or 80-character serial printer to the panel.
PC Log Reports PC Log Reports 17.1 PC Log Reports PC Log Reports This section allows you to program the types of PC Log Reports the panel sends through the 462N Network Interface Card or through the J21 Serial Connector directly on the XR500 Series Canadian panel. The reports include information such as the type of activity, time and date of the activity, and user name and number. These data reports can be accessed from a PC using the Advanced Reporting Module.
PC Log Reports 17.10 Door Acs no YES Door Access Reports Sends door access activity: door number, user number and name, and time and date. 17.11 Supv MSG no YES Supervisory Reports Sends system monitor reports, such as AC and battery, and system event reports.
Area Information Area Information 18.1 Area Information Area Information Allows you to assign functions to the different areas in the system. All non-24-hour zones must be assigned to an active area. See Zone Information. You activate an area by assigning it a name. See Area Name. A name is given to each active area in place of a number to assist the user during arming and disarming. When only areas one to eight are used, the Armed Status display is 1 2 3 4 5 6 7 8.
Area Information 18.5 CLs Chk no YES Closing Check Select YES to enable the panel to verify that all areas in the system are armed after permanent or extended schedules expire. If the Closing Check finds any areas disarmed past the scheduled time, the keypads selected to display System Trouble Status displays CLOSING TIME! and emits a steady beep. When Area Schedules is set to YES in Area Information, the specific area and name display followed by — LATE.
Area Information 18.10.2 18.11 Home/Sleep/Away Programming int bdrm perim When Home/Sleep/Away is selected as the system type, program the Interior, Bedroom, and Perimeter areas as needed. * Unused * Area Name The area name can be up to 32 alphanumeric characters. To add an area name to the system, press any Select key and then enter up to 32 characters for the new area name. Press COMMAND to continue. For instructions on entering alphanumeric characters see section 1.7 Entering Alpha Characters.
Area Information 18.16 18.17 Armed Output: 0 Armed Output Number Late Output: 0 Late Output Number Enter the output to turn on when this area is armed. If an exit delay is used for this area, the Armed Output turns on at the start of the exit delay. The output is turned off when this area is disarmed. The output cannot be turned on from the User Menu Outputs On/Off option.
Zone Information Zone Information 19.1 Zone Information Zone Information Zone Information allows you to define the operation of each protection zone used in the system. All protection zones, whether located on a command processor panel, Security Command keypad, or zone expander are programmed the same way. 19.2 Zone No: - Zone Number Enter the number of the zone you intend to program. Available zone numbers are shown in the table below.
Zone Information 19.4 Zone Type: Blank Zone Type The Zone Type defines the panel response to the zone being opened or shorted. This is called the Alarm Action. There are up to 13 possible alarm action responses depending on the zone type and any restrictions it may have. See the Zone Type chart in the Appendix. When you assign a Zone Type to a zone, automatic zone responses are made. There are 12 Zone Types to choose from.
Zone Information 19.7 Arming Zone Area Assignment arm/dis areas In an Area or Home/Sleep/Away with Guest system, if the zone has been programmed as an Arming Type (AR), enter the areas that the zone controls. When the zone changes from normal to shorted, the programmed areas toggle between the armed or disarmed condition using the Style programming below. When restored to normal, no action occurs. When the zone is opened from a normal (disarmed) state, a trouble is reported.
Zone Information 19.9 Next Zn? No YES Next Zone Select YES to terminate zone programming. The display returns to Zone Number, allowing you to enter a new zone number. Select NO to make alterations to the Alarm Action for a zone. Alarm Action is defined beginning with section 16.12. To program zones for wireless operation, select NO at the NEXT ZONE - NO YES option. The WIRELESS NO YES option displays. If the zone you are programming is intended for wireless devices, select YES.
Zone Information TRANSMTR CONTACT This option displays when programming the 1114 Wireless Four-Zone Expander with four input contacts. The same serial number is used for all four contacts. 1 2 3 4 Select the contact number to program. When using the contacts, you must use consecutive zone numbers. Default is Contact 1. For example, use serial number 08345678 to program Contact 1 for Zone 561, Contact 2 for Zone 562, Contact 3 for zone 563, and Contact 4 for zone 564.
Zone Information 1100 Series Key Fobs For an 1100 Series Key Fob set the House Code from 1 to 50. See House Code programming in System Options. Only zones 400 to 449 can be programmed as 1100 Series Key Fob zones. Refer to the 1100 Series Key Fob Programming Sheet (LT-0706) supplied with the 1100X Wireless Receiver and the 1100 Series Key Fob Install Guide (LT-0703) as needed.
Zone Information 19.11.7 button Action yyy: xxxxxxxx Button Action button Action ARM DIS TGL stA ARM (Arm) - Arms selected areas and force arms bad zones. This option specifies the Button Action for an individual key fob button. The default action for the button selected is displayed. Press any Select key to display the Button Action options. To view more options press COMMAND. yyy = the name of the button being programmed (TOP, BTM, LFT, RGT). DIS (Disarm) - Disarms selected areas.
Zone Information arm areas: PERIM In an All/Perimeter or Home/Sleep/Away system, this specifies the area to be armed by the Key Fob button being programmed. For All/Perimeter systems, choose PERIM or ALL, for Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY. Note: Areas 3 and higher in an All/Perimeter system, and areas 4 and higher in a Home/Sleep/Away system are not available for use. After selecting the areas, for one-button key fobs the Zone No.: prompt displays.
Zone Information FA Series Wireless For an FA Series Remote Wireless Receiver set the House Code to 99. See House Code programming in System Options. Only zones 500 to 699 can be programmed as FA Series Wireless zones for maximum of 200 Wireless Zones. For a DMP 1100X Wireless Receiver see section 16.10. 19.12 19.12.1 zone information Wireless wireless? no yes Select YES to program a wireless zone connected to an FA Series FA400-DMP Remote Wireless Receiver.
Zone Information 19.15 MSG: Trouble A t l D s 19.16 Press any Select key to display the following report options: A, T, L, S, C, and - (dash). - ALARM - Select A to send an alarm report to the receiver and activate the bell output according to zone type. The zone name appears in the panel alarmed zones and status lists. TROUBLE - Select T to send a trouble report to the receiver. The zone name appears in the panel alarmed zones and status lists.
Zone Information 19.18 Swgr byp no YES Swinger Bypass 19.19 Prewarn KEYPADS: Prewarn Keypad Addresses 19.20 Entry Delay: Entry Delay 1 Selecting YES allows the zone to be swinger bypassed by the panel according to the specifications programmed in Swinger Bypass Trips and Reset Swinger Bypass. The Bypass condition displays in the keypad Status List. Selecting NO disables swinger bypassing for this zone.
Zone Information 19.25 Priority no YES Priority Select YES to provide additional protection for the premises by requiring this zone to be in a normal condition before its assigned area can be armed. 19.26 FIRE PANEL SLAVE Fire Panel Slave Input INPUT: no yes This option is available on Fire Zones (FI) only and allows a fire zone the ability to provide slave communication operation for a separate fire alarm control panel.
STOP Stop 20.1 Stop Stop Save Programming WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE RUN AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE THE PROGRAMMING CHANGES. At the STOP prompt, pressing any Select key allows you to exit the Programmer function of the panel. When selected, the panel performs an internal reset and exits the programmer.
Feature Upgrade Feature Upgrade 22.1 FEATURE UPGRADE ENTER KEY - 22.1.1 ENCRYPTION DISABLED Feature Upgrade In the Programming Menu, pressing COMMAND at the SET LOCKOUT CODE prompt displays FEATURE UPGRADE. This allows you to enable additional features in the panel. Press any top row Select key to display the first available feature. ENABLED or DISABLED displays indicating whether this feature is currently used in this panel. Press the COMMAND key to display additional feature(s).
Appendix Appendix 23.1 False Alarm Reduction 23.2 Diagnostics function System Recently Armed report The System Recently Armed report (S78) is sent to the receiver when a burglary zone goes into alarm within two minutes of the system being armed. The XR500 Series Canadian panel contains a Diagnostics function that allows you to test the communication integrity of the LX-Bus™, identify individual zones, and also display the present electrical state of any zone.
Appendix MAC Address Short for Media Access Control address. This hardware address uniquely identifies each network node. Not to be confused with an IP address, which is assignable. In the Diagnostics function, the MAC address is the panel on-board network hardware address. Press any top row Select key to display the panel MAC address. Press the COMMAND key to view the next prompt. Serial Number This number is the network communicator serial number.
Appendix 23.3 Using the 984 Command Function This feature allows you to connect to a service receiver, is used primarily to bring a new account on-line and upload panel programming completed in Remote Link™. Note: When not in the Programming Menu, the function 984 + COMMAND can be entered at the keypad, and a remote options menu appears. This menu contains the following options: NUMBER: The panel allows you to enter into the keypad a phone number you want the panel to dial.
Appendix 23.4 Using the Walk Test The XR500 Series Canadian panel provides a walk test feature that allows a single technician to test the protection devices connected to zones on the system. Conduct the Walk Test within 30 minutes of resetting the panel. The Walk Test automatically ends if no zones are tripped for 20 minutes. TEST IN PROGRESS displays at all keypads programmed with the same Area Display features. When five minutes remain, TEST END WARNING displays.
Appendix If ENHANCED ZONE TEST is selected as YES: A Verify message is sent at the time the zone trip occurs instead of at the end of the Walk Test. For FI, FV or SV zone types, the Verify message is sent at the initial trip. For all other zone types, the Verify message is sent when the zone restores. This allows the Central Station to count the number of devices per zone. END - Select END to stop the Walk Test. When the Walk Test ends or a 20-minute time-out expires, a final Sensor Reset occurs.
Appendix 23.6 23.7 23.8 23.9 Cross Zoning Caution must be taken when cross zoning devices to ensure that the Cross Zone Time is long enough to allow an intruder to trip both devices before it expires. A Cross Zone Time that is too short may allow an intruder to trip the devices and allow only a zone fault report be sent to the central station. When a Cross Zoned zone trips a FAULT report is sent to the SCS-1R Receiver.
Sec Language Re Arm Delay Shift/Time Access Easy Arm/Disarm Anti-passback Temp User Code Extend Schedules Fire Drill Service Request Display Events Time Schedules User Codes User Profiles System Test System Status Zone Monitor Bypass Zones Zone Status Outputs On/Off Armed Area Door Access Sensor Reset Alarm Silence Arm/Disarm Output Areas Access Areas Group Disarm Profile # Profile Name Arm Appendix 1234A 1234A 1234A 1234A 1234A 1234A 1234A 1234A 1234A 1234A 1234A 1234A 1234A 12
Appendix 23.10.1 Wireless Check-in and Supervision Definitions FA Series Check-in Time Explained The check-in time programmed for FA Series wireless transmitters is the number of seconds between each message sent from the transmitter to the FA Series receiver for supervision purposes. This time is programmable for each transmitter from 10, 30, or 60 seconds. Selecting 0 (zero) disables check-in.
FV AR Night Day Exit Fire Panic Emergency Supervisory Auxiliary 1 Auxiliary 2 Fire Verify Arming NT DY EX FI PN EM SV A1 A2 FV AR 1 to 32 T - 0 0 0 A T L D S C S S S T - 0 0 0 S P M F A T L D S C S S S A A A T T T T T T T 0 0 T T 0 0 S S A A 0 0 0 S S 0 0 0 0 0 0 0 0 0 0 S P M F A T L D S C S S S S S S S S S S A A A A A A A A A A S N P M or F Y 0 0 0 0 0 0 0 0 0 0 S S S S S S S S S S or or to 16 4 Y Y Y 1-16 1 N N N N N N N Y 16 N + N N N + + + N N N 0 N 0 N N N N N N
0 0 N N 0 0 TGL MNT 0 0 0 N N N 0 0 Check-in Time 1126 Sensitivity 1126 Pulse Count N N N N N N N N N + + + + + N N N N N 1 1-16 S S 0 0 0 0 A A A A S S 0 0 T T N N N N N N N N N N N INT INT INT INT INT INT INT INT INT INT INT 0 0 Wireless - This indicates wireless equipment is being used. DMP Wireless - These options are for use with the DMP 1100X Wireless Receiver. FA Series Wireless - These options are for use with the FA400‑DMP Remote Wireless Receiver.
Appendix 23.13 Common Keypad Messages There are several common keypad messages that the keypad displays to inform the technician and end‑user. The common messages are described below. Possible solutions are also provided. Message INVALID AREA INVALID CODE INVALID PROFILE INVALID TIME Meaning The user has attempted a door access for an area they are not assigned. The user code you entered is not recognized by the system. A user attempted a function that is outside of the assigned profile.
Appendix 23.
Revisions Revisions to This Document This section explains the changes made to this document during this revision. It lists the version, identifies the change(s) made, the related section number and heading, and a summary of the change. Guide Version Section Number and Heading 1.08 6.4 Access Areas 6.7 Strike Time 6.8 Strike Delay 6.13 Door Real-Time Status 6.14 Send Door Forced Message 6.15 Program 734 Options 7 Remote Options 7.2 Remote Key 7.4 Allow Dialer Remote 7.5 Allow Network Remote 7.
This Class A digital apparatus complies with Canadian ICES-003 NIST Validated XR500E Encrypted Command Processor Panel Certificate #130 ANSI/SIA CP-01-2000 False Alarm Reduction Underwriters Laboratories Canada (ULC) Listed ULC S545 Household Fire ULC Subject-C1023 Household Burglar ULC/ORD-C1076 Proprietary Burglar ULC S304-06 Central Station Burglar 800-641-4282 INTRUSION • FIRE • ACCESS • NETWORKS www.dmp.