Specifications
© 2015 Digital Monitoring Products
iCOMsl Account Numbers: In input mode, the account number entered here is reported to the
receiver.
In keypad mode, the account number reported to the receiver originates from the panel attached to
the iCOMsl. The account number entered here, when in keypad mode, is used for programming with
Remote Link only. The iCOMsl and the panel have separate account numbers.
File > Panel Information
When assigning account numbers, keep the following conventions in mind.
When using Digital Dialer (DD) communication, the range of available account numbers is 1 through
65535. Do not use a leading 0 (zero) if you are assigning an account number of four digits or less.
The panel automatically right justifies the account number if it does not fill the display.
When using Modem IIe (M2E), Contact ID (CID), or 4-2 communication, select an account number
between 1 and 9999.
When using Host/Net (HST/NET) mode, the range of available account numbers is 1 through
65535.
When using Multiplex (MPX) communication, you must select a 5-digit account number as described
below.
The first number is the receiver line number, which is usually 1, and the second number is always
0.
Assign three digits between 000 and 127 as the main panel account number. The full account
number will read between 10000 and 10127.
If you wish to assign separate account numbers to individual areas, then assign an area account
number between 128 and 999. The final account number for areas will read between 10128 and
10999.
When using the iCOMsl, enter an account number between 1 and 65535.
File > Panel Information
To edit information on existing accounts, open the Panel Information window by clicking File > Panel
Information.
To modify the information on an account, select the account on the left side of the Panel Information
window, then change or add the information on the right half of the window. You may also add
additional information to each account by clicking on the Extra Information button to open the
Extended Panel Information window.
File > P anel Information > Copy button