Specifications
© 2015 Digital Monitoring Products
Host Number: 1
Host Name: Select a name for the Receiver Host. Name can be 16-characters.
Host Type: Primary.
Port Type: Serial.
Start Character: Select a start character to precede all host messages. Default is None.
Use CRC: Select to enable CRC error checking on each message sent to the host. Default is disabled.
Use Sequence: Select to enable 1-99 numbering of all messages sent to the host. Default is disabled.
Test Interval (minutes): Enter number of minutes between message tests. The test interval can be
between 1-60 minutes. Default is 1.
Acknowledge Timeout (seconds): Enter the number of seconds (1-15) that the receiver should wait
for an acknowledgment from the host before re-sending the message. Default is 3.
Retries to Failure: Enter the number of retries allowed without receiving an acknowledgment from
the host before entering a failed state. This retry number includes the initial message sent to host.
The retry range may be from 1-15. Default is 3.
Line Number Length: Enter the number of digits, 0 (zero) through 2, used to report the SCS-1R
Receiver signal line number. Default is 0.
Send: Click Send to send the Receiver Host Programming to the SCS-1R.