Specifications

© 2015 Digital Monitoring Products
System > Configure > R emote Link > Other T ab
Admin Reader
When using an Admin Reader to enter User Codes from proximity credentials, configure the COM Port
and Baud Rate here. Refer to the Admin Reader Installation Sheet (LT-0619) as needed.
Note: The Admin Reader USB connects to a standard USB port on a PC and operates as a
virtual COM port requiring a special driver from the following web site.
http://www.ftdichip.com/Drivers/VCP.htm
When using non-DMP proximity credentials, download and adjust the Configuration Utility
values as needed.
http://www.rfideas.com/Software/
COM Port: Select the virtual COM Port to which the Admin Reader is connected.
Baud Rate: Select the baud rate at which the Remote Link communicates with the Admin Reader. The
default Baud Rate is 9600.
Reader Model: Select the connection used for the Admin Reader.
Serial: Select this option when using a Reader connected to a serial port.
USB 6081: Select this option when using a Reader connected to the USB port.
Max Code Length: Select the number of characters, 5-10, for the user code.
Wiegand Length: When using a custom card, enter the total number of bits to be
received in Wiegand code including parity bits. Enter a number between 0-255 to
equal the number of bits. Default is 26 bits.
User Code Position: Enter the user code start bit position. Enter a number between 0-
255. Default is 9.
User Code Length: Enter the number of user code bits. Enter a number between 16-
32. The default is the DMP value of 17 which is pre-programmed.
Set Card Defaults: Select to set the Admin Reader fields based on the current value
of the Max Code Length.
Test: Click the Test button to ensure that you have entered the proper COM Port and Baud Rate.
For more information about the Admin Reader feature, see Scanning a Proximity Card.