Access Areas should be left at factory default settings.
Output Group: You may assign each profile to an output group number from 1 to 20. See Output
Groups for more information.
Profile Options:
Each user profile may be assigned any of the profile options. Select each box for the options you wish
to assign to the profile.
Note: Always be sure that at least one administrator code in your system has a profile with all
authorities and all areas.
Shifts (1 - 4) (XR100/XR500 Series and XR2500F panels): Check the box for each shift where
you want to authorize access for this profile.
Schedules (XR150/XR350/XR550 Series panels): Enter each Schedule number you want to
authorize access for this profile, up to 8 Schedules per profile. Profiles with no assigned Schedules will
have 24-hour access. See Schedules.
Easy Arm/Disarm: When entering a code that has Easy Arm/Disarm enabled, the system will
automatically arm or disarm all areas that are assigned to the code. The ALL NO YES? Option does not
display when this option is enabled in the user profile.
Anytime: Check this box if you would like this profile to operate without regard to schedules.
Note: You may select multiple shifts for each profile. For example, a profile may be allowed
Shift 1 and Shift 2. You may not select individual shifts if you select Anytime.
Re Arm Delay: Allows the entry of 0 to 720 minutes to be used to delay automatic rearming when the
user disarms an area outside of schedule. If zero is selected, the rearming occurs based on Late/Arm
Delay programming in the panel Area Information.
Re Arm Delay is also used to delay a late to close message to the central station when the panel does
not use automatic arming.
If the user has Extend Schedule authority, 2HR 4HR 6HR 8HR displays at disarming. If the user does
not make a choice, the Re Arm Delay is used to extend the schedule.
Applications example: An exit door near the trash is scheduled to be armed at all times. When the
custodian needs to remove trash, program 10 minutes for the activity. Or, an overhead door only
requires access when a delivery is made. Program up to 250 minutes to allow the loading dock
supervisor to load or unload a semi-truck.
Use Secondary Language: Allows the programmed secondary user language to display when the Easy
Arm/Disarm option is enabled and the user presents their credentials or enters their user code at the
Status List.
Card Plus PIN (XR150/XR350/XR550): When checked, all existing user codes assigned to that
profile will need a PIN number assigned. Program the PIN number in Program>User Codes. For door
access, arm/disarm, or User Menu access, the first code must be entered from a proximity patch,
credential card, fob, etc., on a reader from a DMP Keypad (Models 7063, 7163, 7073, 7173, 7872,
7873) or an external reader. The second code is a PIN number keyed in at the keypad or can be a
second credential.
For users with multiple profiles, when Card Plus PIN is checked, a PIN is only required for the Arm/
Disarm or Access areas assigned to that profile.
Note: The Card Plus PIN option is only available on Area Systems.