Report with Account Number for Area:
This option is only available for 24-hour zone types (Fire, Fire Verify, Panic, Emergency, or
Supervisory). Enter the area number (1-32) to assign as a 24-hour zone type. This option sends the
account number of the programmed area with messages. If the entered area number does not exist or
is not valid, the account number programmed in the Communication section is sent. Select 0 (zero) to
have the report sent with the account number programmed in Communication. Default is 0
Prewarn: Enter the keypad addresses that you want to prewarn during the entry delay. All keypad
addresses designated in this field display "ENTER CODE: -"
To enter a keypad address, click once in the field to select it and type the number key for the desired
keypad address. The number appears in the field. To turn off an address number, type the number
that appears in the Prewarn field that you wish to remove.
Note: On XR150/XR350/XR550 Series, XR500 Series, XR2500F, XR100 Series, and XR40 panels,
the prewarn tone stops at the keypad when the first user code digit is entered. If no keys are
pressed for five seconds or an invalid user code is entered, the prewarn tone resumes.
Note: XR550 Series, XR500 Series and XR2500F panels support up to 32 keypads. XR350 Series
panels support up to 16 keypads. All other panels support up to eight keypads.
Presignal: If Retard is selected for a zone, the Prewarn field changes to the Presignal field. A
presignal tone is indicated by a warning tone sounding from the keypad, but not from any other
notification devices, and no signal is sent to the central station. Presignal allows you to enable any
combination of keypad addresses to sound a presignal tone during the time a zone is in retard delay.
Retard only functions in zone short conditions.
Armed Areas (XT30, XT50, XTL, XTLN, XTLN-WiFi, XRSuper6, XR20, XR40): When Arming is
selected as the Zone Type, the Prewarn field changes to Armed Areas. Select the area numbers to be
armed when this zone is faulted.
Entry Delay Number: Select the entry timer for this zone. The Entry Delay Number refers to the Entry
Delay fields in the System Options window. Enter a number (1 to 4) to assign the entry delay time for
each exit-type zone.
Program > Zo ne Informatio n
Prewarn: Enter the keypad addresses that you want to prewarn during the entry delay. All keypad
addresses designated in this field display "ENTER CODE: -"
To enter a keypad address, click once in the field to select it and type the number key for the desired
keypad address. The number appears in the field. To turn off an address number, type the number
that appears in the Prewarn field that you wish to remove.
Note: On XR150/XR350/XR550 Series, XR500 Series, XR2500F, XR100 Series, and XR40 panels,
the prewarn tone stops at the keypad when the first user code digit is entered. If no keys are
pressed for five seconds or an invalid user code is entered, the prewarn tone resumes.
Note: XR500 Series and XR2500F panels support up to 16 keypads. XR350 Series panels
support up to 16 keypads. All other panels support up to eight keypads.
Presignal: Enter the keypad addresses that you want to sound a presignal tone during the time a zone
is in retard delay. The presignal tone silences when the zone restores or the retard delay expires. You
may only select Presignal when Retard is selected.
Armed Areas (XT30, XT50, XRSuper6, XR20, XR40): When Arming is selected as the Zone Type,