Specifications
© 2015 Digital Monitoring Products
selected. Any area may be selected at Arm/Disarm Areas but only matching area numbers are armed
or disarmed when the specific button is pressed. For example, in Areas selection, areas 1, 3, and 7
are selected. In the User Profile Arm and Disarm Areas, areas 1, 2, 4, and 7 are selected. When the
user presses the button to Arm or Disarm area(s), only matching areas 1 and 7 Arm/Disarm.
Note: When more areas are selected at Arm/Disarm Areas than are authorized in the User
Profile, in the future the user can be given access authority to additional areas through the
User Profile without requiring additional panel programming to select Arm/Disarm Areas.
When the XT30, XT50,XTL, XTLN, XTLN-WiFi, XRSuper6, XR20, XR40, XR100/XR500 Series, or XR150/
XR350/XR550 Series panel is configured for All/Perimeter or Home/Sleep/Away system operation,
specify the area to be armed by the Key Fob button being programmed. For All/Perimeter systems,
choose PERIM or ALL, for Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
Note: On XR150/XR350/XR550 or XR100/XR500 Series panels, Areas 3 and higher in an All/
Perimeter system, and areas 4 and higher in a Home/Sleep/Away system are not available for
use.
Output Number: Specify the output number the key fob button press activates for OUT, PN, PN2, EM,
EM2 programmed buttons. A different output number can be assigned to each key fob button.
1 to 4, 31-34 or 41-44 on XT30, XT50, XTL, XTLN, XTLN-WiFi, XRSuper6, XR20, or XR40 panels.
1 to 6, 500 to 999, D1 to D16, or G1 to G20 on XR500 Series and XR550 Series panels.
1 to 6, 500 to 599, D1 to D8, or G1 to G20 on XR100 Series and XR150 Series panels.
1 to 6, 500-799, D1 to D16, F1 to F20, or G1 to G20 on XR350 Series panels.
Output Action: When programming the relay output action taken by the panel when a valid Output
Number is entered, select from the following action options:
Steady: The output is turned on and remains on continuously.
Pulse: The output alternates one second on and one second off. The pulsing rate for a Model 716
relay attached to the LX-Bus is 1.6 seconds.
Note: Pulse is not available for key fob button outputs programmed D1 to D16 or G1 to G20.
Momentary: The output is turned on only once for one second.
Toggle: The output alternates between the on state and off state.
Note: Toggle is not available for key fob button outputs programmed G1 to G20.
Off: The output is turned off. If programmed, the output was turned on by some other means
such as another button press, a zone action, or a schedule.
Notes: When the output is assigned to PN/PN2 or EM/EM2 button action and is turned on, the
output turns off when any area is disarmed.
When the output action is steady, pulse or toggle and the output is turned on, the output remains on
until:
- the output cutoff time expires
- the output is reset from the keypad menu
- toggled off