Specifications
© 2015 Digital Monitoring Products
assignments, however, the User Number does not have to exist at the time the Key Fob is
programmed. The Key Fob User Number can be added later by the User.
Serial Number: Enter the eight-digit serial number found on the key fob.
Supervision Time: Select the supervision time required for the key fob zone. The wireless transmitter
must check in at least once during this time or a missing condition is indicated for that zone. Select 3,
60, or 240 minutes. Select None for unsupervised operation. Default is None.
Number of Buttons: Select the number of buttons (1, 2, or 4) on the key fob being programmed.
Button Action: When programming a key fob button, select from the following action options:
Arming: When selected, pressing this button arms selected areas and force arms bad zones.
Disarming: When selected, pressing this button disarms selected areas.
Toggle Arm/Disarm: When selected, pressing this button changes the armed state of selected
areas. If arming, bad zones are force armed. When pressed again, the opposite action occurs.
Status: When selected, pressing this button causes the key fob LED to indicate the system arm/
disarm status.
Panic: When selected, pressing this button sends a Panic type alarm with no restoral.
Panic 2 Btn: To operate as a panic type alarm, program two buttons using PANIC 2 BTN. When
both buttons are pressed at the same time a Panic type alarm is sent with no restoral. If only
one button is pressed, no action takes place.
Emergency: When selected, pressing this button sends an Emergency zone type alarm with no
restoral.
Emergency 2 Btn: To operate as an emergency type alarm, program two buttons using
EMERGENCY 2 BTN. When both buttons are pressed at the same time an emergency zone type
alarm is sent with no restoral. If only one button is pressed, no action takes place.
Output: When selected, pressing this button causes an output to turn on steady, pulse,
momentary, toggle or off as programmed.
Sensor Reset: When this button is pressed the panel performs a standard Sensor Reset.
Unused: When this button is pressed, no operation or action takes place.
Button Press Time:
Select the amount of time for the user to press the button before the
action initiates a message to the wireless receiver. The Button Press Time can be SHORT (1/2 second)
or LONG (2 seconds). Select Button Press Time for Arm, Disarm, Toggle, Status, Output, or Sensor
Reset buttons.
Note: The Button Press Time is not programmable for Panic (PN or PN2), Emergency (EM or
EM2) or Unused (UN) zones. For these zones the button time is always set to LONG (2
seconds).
Arm/Disarm Areas: On an Area system or Home/Sleep/Away with Guest system, enter the area
numbers to be armed/disarmed by the Key Fob button being programmed.
XT30, XT50, XTL, XTLN, or XTLN-WiFi - Areas 1-6
XR20, or XR40 - Areas 1-4
XR100 or XR150 Series - Areas 1-8
XR350 Series - Areas 1-16
XR500 or XR550 Series - Areas 1-32
On XR150/XR350/XR550 Series or XR100/XR500 Series panels, list all areas that apply. In order to arm
or disarm these areas, the Profile assigned to the User Number needs to have the same area numbers