expanders, cannot use this address. Zones connected directly to the panel cannot be wireless.
Disarm/Disable
This option displays for 1103 Universal Transmitters, and 1126, 1127 Wireless PIRs. Select this option
to disable the zone tripped message (short) to the 1100X Series Receiver from the PIR transmitter
during the disarmed period. When disabled, the PIR only sends supervision, tamper and low battery
messages during the disarmed period to extend the transmitter battery life. Select NO to always send
zone tripped messages in addition to supervision, tamper and low battery. Default is NO.
Wireless PIR Pulse Count
This option displays for 1126 and 1127 Wireless PIRs. Select the number of infrared pulse counts (2 or
4) the PIR will use before sending a short message to the 1100X Series Receiver. The first infrared
pulse starts a timer and count. If no additional infrared pulses occur in 25 seconds, the timer and
count are reset. Default is 4.
Wireless PIR Sensitivity
This option displays for 1126 and 1127 Wireless PIRs. Select the sensitivity setting for the PIR.
Selecting LOW sets the PIR to operate at 75% sensitivity for installations in harsh environments.
Selecting HIGH sets the PIR to maximum sensitivity. Default is LOW.
Program > Zone Information
Wireless:
Select this option if the zone you are programming is DMP wireless.
XR150/XR350/XR550 Series or XR100/XR500 Series panels Version 113 and
higher, connect to the DMP 1100X, 1100XI, or 1100XH Wireless Receiver.
XT30, XRSuper6, XR20, or XR40 panels connect to the DMP 1100D, 1100DI, or
1100DH Wireless Receiver.
XT50 with on-board 1100 Series Receiver.