Specifications

© 2015 Digital Monitoring Products
Program > Zo ne Informatio n > Wireless Tab
Wireless: Select this option if the zone you are programming is DMP wireless.
XR150/XR350/XR550 Series or XR100/XR500 Series panels Version 113 and higher, connect
to the DMP 1100X, 1100XI, or 1100XH Wireless Receiver.
XT30, XT50, XRSuper6, XR20, or XR40 panels connect to the DMP 1100D, 1100DI, or 1100DH
Wireless Receiver.
XT50 with on-board 1100 Series Receiver.
XTL with on-board 1100 Series Receiver.
XTLN, XTLN-WiFi with on-board 1100 Series Receiver.
Serial Number: Enter the eight-digit serial number found on the wireless device. When the panel zone
stores the serial number, the panel House Code is transmitted to that specific transmitter. This
transmission is performed by the DMP Wireless Receiver when Remote Link disconnects.
All DMP wireless programming is stored in the panel. The DMP Wireless Receiver obtains the necessary
programming information from the panel:
Each time the receiver is powered down and powered up
When a new receiver is installed
When the programmer STOP routine is selected
When the panel is reset
When Remote Link disconnects
The receiver memory refresh takes up to 45 seconds to complete depending on the number of DMP
wireless zones programmed. Normal DMP receiver operation is inhibited during the memory refresh
period.
Contact:
Universal Transmitters: Choose Internal to use the internal reed switch contacts or choose External
to connect an external contact to the 1101, 1103, or 1105 terminal block. Default is Internal.
Note: The DMP 1101, 1103, or 1105 Universal Transmitter serial number may be programmed