Specifications

© 2015 Digital Monitoring Products
Door Access/Denied
User 1 Ambush and Early Morning Ambush
System Test Begin/End
Unauthorized Entry
Service Code and Service Request
The XR150/XR350/XR550 Series and XR100/XR500 Series sends the following messages using the area
account number based on the area number:
Late to Arm for area schedules
Bad Zones: Some zones may not be in a normal condition at the time that they are to automatically
arm. This option allows you to program the panel's response to these faulted zones.
Bypass: This option will bypass all bad zones upon arming. A report of the bypass is sent to the
receiver if you select Bypass in the System Reports window.
Force Arm: This option will force arm all bad zones upon arming. Zones that are force armed are
capable of restoring and reporting an alarm if tripped. A report of the force arm is sent to the receiver
if Bypass is selected in the System Reports window.
Refuse Arm: This option will refuse automatic arming in the event of a bad zone at arming. The
panel sends a "No Closing" report to the receiver regardless of whether Closing Check is selected in the
Partition Information or System Area Information window.
Armed Output: Enter the output number to turn on when this area is armed. The specified output will
turn off while the area is disarmed.
Late Output: Enter the output number to turn on at the expiration of a closing schedule. The output
will activate simultaneously with the "CLOSING TIME!" keypad display. This output turns off when the
late area is armed, the closing is extended, or the schedule is changed.
Late/Arm Delay (XR150/XR350/XR550 Series, XR500 Series, XR2500F, XR100 Series): Enter
4 to 250 minutes to delay before automatic arming occurs after the area becomes disarmed outside of
schedules. See Closing Check. Default is 60 minutes.
Auto Arming: Selecting this box will allow this area to arm automatically as scheduled. If no
schedules are programmed and this option is selected, the area will auto arm every hour. Leaving the
Auto Arm box empty will disable automatic arming for this area.
Upon automatic arming, bad zones are handled according to the option selected in the Bad Zones field.
If Closing Check is selected in the Partition Information window, the automatic arming function does
not take place until the expiration of a 10-minute closing check delay. If the area has been disarmed
outside of a programmed schedule, the closing check sequence occurs one hour after the area is
disarmed.
On XR500 Series or XR2500F panels, if within ten minutes after the schedule expires, the system is
not armed or a temporary schedule is not entered to extend the closing time, a Late to Close report is
sent. When Auto Arm is YES, the area arms. If the area becomes disarmed outside of any schedule,
the Closing Check sequence occurs after the Late/Arm Delay time.
When Closing Check is NO and Automatic Arming is YES, the system immediately arms when the
schedule ends. No warning tone occurs. When NO is selected at the Closing Check prompt, the Extend
Time option does not display when a schedule expires.
Auto Disarm: When this option is selected, the area automatically disarms according to schedule. Not
selecting this box will disable automatic disarming by schedule for the area.
Note: For XR100/XR500 Version 200 or lower, when the SIA CP-01 option in System Options is