Specifications

© 2015 Digital Monitoring Products
When Closing Check is NO and Automatic Arming is YES, the system immediately
arms when the schedule ends. No warning tone occurs. When NO is selected at the
Closing Check prompt, the Extend Time option does not display when a schedule
expires.
A uto Disarm :
When this option is selected, the area automatically disarms
according to schedule. Not selecting this box will disable automatic disarming by
schedule for the area.
Note: For XR100/XR500 Version 200 or lower, when the SIA CP-01 option in
System Options is set to NO, the Interior area auto disarm does not occur if
an exit zone is not tripped during the exit delay time.
Bank Safe & Vault:
When this option is selected, the area can only be disarmed
during scheduled times. Not selecting this box will disable Bank Safe & Vault
mode for this area.
Note: Do not assign Bank Safe & Vault areas to an Arming zone. Arming
zones can disarm Bank Safe & Vault areas outside of a schedule.
Common A rea:
Selecting this box will enable the area to operate as a common
area. This area is armed when the last area in the partition is armed and is
disarmed when the first area in the partition is disarmed. You can have multiple
common areas in each partition.
T wo Man R ule:
Checking this box will require two user code entries to disarm or
allow door access in this area. When a user presents a code to a keypad or reader
requesting door access or disarm, the keypad will display "2ND CODE". A second
user code with at least the same authority must be entered to allow entry or to
disarm.
A rm First:
Enables the area to operate as an Arm First area. This area
automatically arms when any non-Arm First area assigned to the same keypad is
armed but does not disarm when other areas become disarmed. If an Arm First area
has faulted zones that cannot be bypassed, arming stops. Default value is NO.
Description:
Enter a note about the area that you are programming. To enter a
note or description, press the Description button to open the Edit Rich Text
window. After you type your note, go to File > Save and Exit to save your work
and close the Edit Rich Text window. Your note appears in the field above the
Description button.