Specifications

© 2015 Digital Monitoring Products
Late to Arm for area schedules
Bad Zones:
Some zones may not be in a normal condition at the time that they are to
automatically arm. This option allows you to program the panel's response to these faulted zones.
Bypass:
This option will bypass all bad zones upon arming. A report of the bypass is sent to the
receiver if you select Bypass in the System Reports window.
Force A rm :
This option will force arm all bad zones upon arming. Zones that are force armed
are capable of restoring and reporting an alarm if tripped. A report of the force arm is sent to the
receiver if Bypass is selected in the System Reports window.
Re fuse A rm:
This option will refuse automatic arming in the event of a bad zone at arming.
The panel sends a "No Closing" report to the receiver regardless of whether Closing Check is
selected in the Partition Information or System Area Information window.
A rmed Output:
Enter the output number to turn on when this area is armed. The
specified output will turn off while the area is disarmed.
Late Output:
Enter the output number to turn on at the expiration of a closing
schedule. The output will activate simultaneously with the "CLOSING TIME!" keypad
display. This output turns off when the late area is armed, the closing is extended,
or the schedule is changed.
Late/A rm Delay (XR150/XR 350/XR550 Series, XR500 Series, XR2500F,
XR100 Series):
Enter 4 to 250 minutes to delay before automatic arming occurs
after the area becomes disarmed outside of schedules. See Closing Check. Default
is 60 minutes.
A uto A rm ing:
Selecting this box will allow this area to arm automatically as
scheduled. If no schedules are programmed and this option is selected, the area will
auto arm every hour. Leaving the Auto Arm box empty will disable automatic
arming for this area.
Upon automatic arming, bad zones are handled according to the option selected in
the Bad Zones field.
If Closing Check is selected in the Partition Information window, the
automatic arming function does not take place until the expiration of a 10-minute
closing check delay. If the area has been disarmed outside of a programmed
schedule, the closing check sequence occurs one hour after the area is disarmed.
On XR500 Series or XR2500F panels, if within ten minutes after the schedule
expires, the system is not armed or a temporary schedule is not entered to extend
the closing time, a Late to Close report is sent. When Auto Arm is YES, the area
arms. If the area becomes disarmed outside of any schedule, the Closing Check
sequence occurs after the Late/Arm Delay time.