Specifications
© 2015 Digital Monitoring Products
If you are using a direct connection to a Remote Link computer through the 462N card on an
XR200/XR200-485/XR2400F panel.
If you are using iCOM/iCOM-E to only send PC Log Reports.
Use the Remote IP Address programmed in the iCOM/iCOM-E.
When using an XR500N/XR500E/XR2500F/XR100N, enter the following address string:
AT#UCXXX.XXX.XXX.XXX#PPPPP to direct PC Log reports to a new address using the J1 Ethernet
connection. The Xs represent the target IP Address, and the Ps represent the port number. The default
port number is 2001. An example of a PC Log Address string is: AT#UC192.168.001.099#2001.
When using an XR200/XR200-485/XR2400F/XR500 and your PC/Host Reports network device is the
same iCOM/iCOM-E as used for Central Station alarm communication, enter the following address
string: AT#UCXXX.XXX.XXX.XXX#PPPPP to direct Log reports to a new address. The Xs represent the
iCOM/iCOM-E target IP Address, and the Ps represent the port number. The default port number is
2001. An example of a Network setup is: AT#UC192.168.001.099#2001.
Note: The PC Log Address CANNOT be the same as that entered in Communication remote IP
address.
Arm / Disarm Reports: Sends arming, disarming and Late to Close events. Includes the area
number, name and action, the user number and name, and the time and date.
Zone Reports: Sends changes in the status of active zones. Includes the zone number, name, and
type as well as the action (alarm, trouble, bypass, etc.) user number (if applicable) and area name.
When the Walk Test or Panic Zone Test (XR150/XR350/XR550 Series with Network or Encryption,
XR500N, XR500E, XR2500F, XR100N or 485B only) is performed, Verify and Fail messages are also sent
for each zone.
User Command Reports: Sends user code changes, schedule changes, and door access denied
events.
Door Access Reports: Sends door access activity. Includes the door number, first and second (485B
only) user number, first and second (485B only) user name, and the time and date.
Supervisory Reports: Sends system monitor reports, such as AC and battery, and system event
reports. Supervisory Reports also sends the following reports:
Abort
Alarm Bell Silenced
System Recently Armed
Ambush
Exit Error
Unauthorized Entry
Late to Close (only sent as a Supervisory Report if Area Schedules is not enabled, Closing
Check is enabled, and an opening/closing schedule has been programmed.)
Note: To send these reports through the PC/Host Log, you must enable Supervisory Reports.
Real-time Status (XR150/XR350/XR550 Series and XR100/XR500 Series Version 203 or
higher): Select to send Real-Time Status reports for selected zones, doors, and outputs. The specific
reports must also be selected by individual zone or output. The Real-Time Status messages are sent to
a PC running a graphic display software. The messages that can be sent are:
Door Open with zone number
Door Closed with zone number