Monitoring, do not enable PC/Host Log Reports. The Advanced Reporting Module will generate
reports using the same messages sent to Alarm Monitoring or the Command Center.
Note: The network connection that the PC/Host Log Reports are sent through is not monitored
for network trouble. PC/Host Log Reports is intended as an auxiliary log of panel activities
and is not intended nor designed for Central Station Monitoring.
If there is trouble with the network connection, the panel will continue to attempt to send the
PC/Host Log Reports until the connection is reestablished. The panel will then send the
reports. Also, a Network Trouble message will not be sent if the connection is lost. The PC/
Host Log Reports have the lowest priority of panel reports sent.
PC/Host Log Reports CANNOT be sent to an SCS-1 or SCS-1R Central Station Receiver.
Comm Type: Select the Communication Type for the panel to send the PC Log Reports. Default is
None.
Net Options
Net IP Address: This option displays when the Communication Type is Net. Enter the IP address
containing up to 16 characters.
Net Port: This option displays when the Communication Type is Net. Enter the port number. Valid port
numbers are from 0 to 65535. Default is 2001.
232 Options
232 Port: This option displays when Communication Type is 232. To enable PC Log Reports, select
either the on-board connector (O) or select A, B, C, D or E for the corresponding slot in use on the DMP
Model 462N Network Interface card. The slots are labeled from left to right, beginning with A. Default
is 0.
232 Setup String: This option displays when the Communication Type is RS-232. Enter up to a 32
character modem string.
PC Log Address (XR500 Series/XR2500F Version 121 or lower) or Host Setup String (XR200/
XR2400F/ XR200-485): Enter up to two lines of 16 characters to equal 32 characters for the IP
address string that is sent to the network device to allow PC Log messages to be sent to a PC through
an IP Network.
Do not enter a PC Log Address string:
If you are using a direct connection through the 462N card to a Remote Link computer or if you
are using J21 Serial Connector on an XR500N/XR500E/XR2500F/XR100N panel for PC Log
Reporting.