Specifications

© 2015 Digital Monitoring Products
output, no additional programming is needed. Select 3, 60, or 240 minutes. On XTLN, XTLN-WiFi, XTL
Version 105, XT30/XT50 Version 106, XR100/XR500 Series Version 207, and XR150/XR350/XR550
Series panels, the 3 minute supervision time is only available if using an 1135/1135DB Wireless Siren.
Select None for unsupervised operation. Default is 240 minutes.
Note: When the panel is reset, a receiver is installed or powered up, or Remote Link
disconnects, the supervision timer restarts for all wireless outputs.
Trip with Panel Bell (XR150/XR350/XR550 Series, XR100/XR500 Series Version 207 or
higher, XT30/XT50 Version 106 or higher, XTL, XTLN, and XTLN-WiFi): Select this option to have
the 1135/1135DB wireless siren follow the panel's bell output cadence for the zone type and bell cutoff
time up to 15 minutes. Default is YES.
Description: A description or note can be assigned to each Output Name in the field on the right side
of the Output Information window. To enter a note or description, press the Description button to
open the Edit Rich Text window. After typing the note, go to File > Save and Exit to save the work and
close the Edit Rich Text window. The note appears in the field above the Description button.