Bypass Limit (XR150/XR350/XR550 Series/XR500 Series/XR2500F/XR100 Series): Enter the
maximum number of zones (0 to 8) that can be bypassed in an area when that area is being armed.
This limit is only in effect when arming from the keypad. Entering 0 (zero) disables this function
allowing an unlimited number of zones to be bypassed. Default is 0.
Occupied Premise (XT30/XT50, XR150/XR350/XR550 Series/XR500 Series/XR2500F/XR100
Series Version 201 or higher): For All/Perimeter or Home/Sleep/Away systems, select this option
to allow the panel to automatically disarm the interior area(s) when arming all areas and a perimeter
exit zone is not tripped during the exit delay. This False Alarm Reduction feature will keep a user from
arming the entire system when they do not exit and remain in the premise. Select NO to disable this
feature. Default is checked. Deselect to disable this feature.
Note: With a Home/Sleep/Away with Guest arming system, this feature only applies to the
main system.
Inactive User Code Audit (XR150/XR350/XR550 Series and XR500 V210 or higher)
This option allows users to choose the number of days a user code can remain unused before the panel
sends an Inactive User Code message to the receiver. The range is 0-365 days.
Weather Zip Code (XT30/XT50, XR150/XR350/XR550 Series and XR100/XR500 V212 or
higher)
This option allows local U.S.A. weather updates to display on the keypad. Enter the zip code of the
user at this prompt. When no number is entered, weather conditions are not displayed. Default is
blank.
SIA CP-01: When selected, the panel operates according to SIA CP-01 standards for the following
operations:
Power Up and Stop Routine - the 60 second zone startup delay is turned on.
Keypress Alarm Silence - during an alarm, the keypad alarm and bell output turn off when the
first key is pressed at a keypad.
Entry Delay - entering the first digit of a code at the keypad stops the keypad prewarn tone.
Exit Delay - the keypad displays the Exit Delay time countdown and annunciates a tone at 8 second
intervals until the last 10 seconds when annunciation is at 3 second intervals.
Exit Error Operation for Entry Delay 1
When the exit zone is faulted (door still open) at the end of the exit delay:
- the bell sounds for the length of time set in Bell Cutoff programming
- the Entry Delay operation starts, requiring code entry to disarm
- if not disarmed, a zone alarm and an Exit Error are sent to the receiver
Automatic Disarming Operation - The Interior automatically disarms if an exit zone is not tripped
during the Exit Delay time when arming All or Away.