Specifications
© 2015 Digital Monitoring Products
Wireless House Code (XR150/XR350/XR550 Series, XR500 Series Version 113 and higher,
and XR100 Series): When using DMP 1100 Series Wireless, enter a House Code between 1 and 50 for
the wireless system to use. The DMP 1100X Wireless Receiver automatically programs the house code
into the wireless transmitters when the unique transmitter serial number is programmed into the
panel. See DMP Wireless Options in Zone Information.
Default is 0 indicating no wireless is being used.
The house code identifies the panel, receiver, and transmitters to each other. When operating, the
receiver listens for transmissions that have the programmed house code and transmitter serial
number.
Note: The flexibility of DMP two-way wireless operation allows an existing house code to be
changed in the panel at any time. The transmitters may take up to two minutes to learn the
new house code and continue operation.
Note: When any wireless zone programming is changed in the panel, wireless receiver zone
programming is updated. At that point, all wireless zones display as normal for approximately
one minute, regardless of the actual state of the zone.
When using FA Series Wireless on XR150/XR350/XR550 Series, XR500 Series, or XR2500F panels,
enter 99 for the house code.
Detect Wireless Jamming (XR150/XR350/XR550 Series, XR500 Series Version 114 and
higher, and XR100 Series): This option displays when using DMP 1100 Series wireless devices and
the programmed House Code is between 1 and 50. When selected and the wireless receiver detects
jamming, a trouble or alarm message is sent to the central station receiver.
Wireless Audible Annunciation: This option displays when the House Code entered is for a DMP
1100 Series Wireless system (1-50). Select the keypad buzzer annunciation method for wireless
troubles. Select ANY to enable annunciation anytime. Select DAY to enable annunciation except during
sleeping hours (9 PM to 9 AM). Select MIN (minimum) to annunciate only Fire and Fire Verify zones
during daytime hours (9 AM to 9 PM). Default is DAY.
Keypad Panics Enabled (XR150/XR350/XR550 Series, XR500 Series Version 114 and higher,
and XR100 Series): When selected, the two-button panic key operation programmed at the keypad
sends Panic, Emergency, or Fire messages to the central station receiver. When not selected the two-
button panic operation is disabled.
Enhanced Zone Test: Select this option to enable Enhanced Zone Test operations. The default is
unchecked.
Enhanced operation allows:
Panic Test and Walk Test functions can be restricted to operate only during an Area 32, Shift 4
schedule if programmed.
A Verify message is sent each time a zone is tested. If a zone is tripped multiple times, a Verify
message is sent for each trip. This allows the Central Station to record the number of devices
per zone.
The Verify message for each zone test is sent at the time the trip occurs instead of at the end
of Walk Test. The System Test Begin and System Test End Central Station messages indicate
the type of zone being tested. The System Test Begin message also includes the user name and
number.
Send 16 Char Names: This option allows the central stations to select being sent either the first 16
characters of the name field or the entire programmed name, up to 32 characters, for user name, user
profile, zone name, area name, output name, and group name.