Specifications
© 2015 Digital Monitoring Products
Program > System Options
Swinger Bypass Trips: Enter the number of times (1-6) a zone can go into an alarm or trouble
condition within one hour before being automatically bypassed. Bypassed zones are automatically reset
whenever the area they are assigned to is disarmed. All 24-hour zones are reset when any area of the
system is disarmed. Entering 0 (zero) disables this function.
Note: The panel hour timer starts at 59 minutes past the hour. If the hour timer expires
before the trip counter is exceeded, the trip counter returns to zero. If the trip counter is
exceeded before the hour expires, the panel automatically bypasses the zone. A report of the
automatic bypass is sent to the receiver if Bypass Reports is checked in Program > System
Reports.
Occupied Premise : When selected, this allows the panel to automatically disarm the interior area(s)
when arming all areas and a perimeter zone is not tripped during the exit delay.
This False Alarm Reduction feature will keep a user from arming the entire system when they do not
exit and remain in the premise. Select NO to not automatically disarm interior area(s). Default is
checked.
Program > System Options
Options - XR500 Series
Options - XR550 Series