Specifications
© 2015 Digital Monitoring Products
Use Built-In 1100: Select this option if using the built-in wireless on the XT50. If selected, zones 80
and 85-99 are available to be programmed as wireless zones. If this option is not checked, then zones
80 and 85-99 are not available. Default is enabled.
Keypad Panics Enabled: When selected, the two-button panic key operation programmed at the
keypad sends Panic, Emergency, or Fire messages to the central station receiver. When not selected
the two-button panic operation is disabled.
Use False Alarm Question (XT30/XT50/XTL Version 108 and higher/XTLN/XTLN-WiFi)
This option allows an alternate display at the keypad when a burglar alarm occurs.
When selected, the keypad displays “IS THIS A FALSE ALARM? NO YES” rather than “CANCEL
VERIFY”. Default is enabled.
Program > System Options
Arm/Disarm Activity Days: Select the number of days a
countdown timer is set for area arming and disarming activity.
The range for the countdown timer is 00 to 99 days. Each time
an area is armed or disarmed, the timer is restarted. When the
timer counts down to zero because of no arming or disarming
activity, the panel sends a "XX Days No Arming/Disarming"
message to the receiver. After the message is sent, the timer
does not restart until a panel reset occurs or an area is armed
or disarmed.
Note: For the message to be sent to the receiver, Supervisory/
Troubles must be selected in Panel > Communications >
Receiver 1 or Receiver 2.
Zone Activity Hours: Allows you to select the number of hours a countdown timer is set to monitor
for non-activity. The range for the countdown timer is 0 to 9 hours. The countdown timer starts when
the panel is disarmed.
Note: This feature is used to monitor a person for non-activity. This could be used for a
person living alone to detect when they have not tripped a disarmed zone within a
programmed period of time.
Entry Delay 1: Enter the Entry Delay time for all exit-type zones programmed to use Entry Delay 1.
When an armed Exit type zone is faulted, the keypad prewarn tone begins sounding. "ENTER CODE: -"
and the name of the zone causing the Entry Delay displays on all keypads.
When the first digit of a code is entered, the prewarn tone stops at the keypad. If, within five
seconds, a valid user code is not entered or an invalid user code is entered, the prewarn tone begins
sounding again. Fifteen seconds must elapse before entering a digit silences the prewarn tone again.
Note: For XR100/XR500 Version 200 or lower, when the SIA CP-01 option in System Options is
not enabled, the first digit entered at the keypad does not stop the prewarn tone.
The area must be disarmed before the entry delay expires or an Alarm Message is sent to the receiver
and an alarm sounds. All Burglary type zones in all areas are delayed along with the Exit zone.
Entry delay times can be from 30 to 250 seconds. Repeat the above for Entry Delay 2 if it is being
used. Default is 30 seconds for Entry Delay 1.
Note: Specific Exit Error operation is based on the Entry Delay used (1 or 2) with an EX type