Zone Restorals: This option allows you to control
when and if a zone restoral report is sent to the
central station receiver. There are three options for
how the panel will send zone restoral messages.
Yes: Enables the zone restoral report option.
Zone restorals are sent each time a zone restores
from a trouble or alarm condition.
No: Disables the zone restoral report option.
Zones continue to operate normally but do not
send restoral reports to the receiver.
Disarm: Enables the panel to send non-24-hour
zone restoral reports whenever a zone that has
restored from a trouble or alarm condition is
disarmed. All 24-hour zones send restoral reports
as they restore.
Access Keypad Enable: Enter the keypad
addresses, 1 through 8, that you wish to send door
access reports to the receiver. A report is sent with
each door access made from the selected keypads. The report includes the user name and number,
and the address of the keypad accessed by the user.
Keypads at addresses not selected still operate the door strike, but do not send door access reports to
the central station.
Note: On XR200-485 panels, selecting addresses 1 through 8 will also select the corresponding
address from 9 through 16: For example, selecting address 1 also selects address 9 and
address 2 also selects address 10.
Enter the sequence of addresses separated by commas to enable door access reports; i.e. addresses 1
through 4, 6 and 10 through 16 would be entered as 1-4,6,10-16 in the Access Keypad Enable field.
Opening/Closing Reports: This option allows the selection of Opening/Closing Reports and the
number of reports sent to the receiver.
No: No opening and closing reports are sent.
Yes: Sends opening and closing reports for each programmed area.
LTD (Limited): Send only one opening and one closing report. When LTD is selected and all areas
become armed, the panel sends a General Closing Report. Then after the first disarming, the
panel sends a General Opening Report. Therefore, when LTD is selected the panel will only send a
report after all areas are armed and then at the first disarm of an area. All openings and closings
will be logged in the panel's event buffer. LTD is only available when the communication type is
CID or M2E. Refer to Communication Type.
ALM (Alarm): Sends only one opening report if an alarm has occurred during the last armed cycle.
The panel will send a General Opening Report. The panel does not send closing reports when ALM
is selected. All openings and closings will be logged in the panel's event buffer. This option is only
available when the communication type is CID or M2E. Refer to Communication Type.
Abort Reports: Programs the panel to send an Abort Signal Received (S45) message to the receiver.
This abort report is sent any time an area is disarmed after an alarm report has been sent and the bell
cutoff time has not expired.