Specifications

© 2015 Digital Monitoring Products
XT30/XT50/XTL/XTLN/XTLN-WiFi Panel:
Options
Remote Key: Enter a numerical code up to eight digits long for the panel to use as a password to
verify its identity to the Remote Link computer. The panel must give the correct key to Remote Link
before any programming may take place. All panels ship from the factory with the key preset as blank.
The Remote Key must match the number entered in the Remote Key field in the Panel Information
window. For security reasons, the Remote Key cannot be viewed from a keypad connected to the
panel.
Remote Disarm: Check the Remote Disarm box to allow the panel to be disarmed remotely. Default
is enabled.
App Key (XT30/XT50 Series Version 112 or higher): Enter the 8-digit App Key obtained in your
Dealer Settings tab at vk.securecomwireless. com. This option is a security feature of the Virtual
Keypad iPhone/Android App used only when your Dealer Settings at vk.securecomwireless.com have
“persistent set as the Communication Type. This communication option is only available for panels
with onboard network and is used to eliminate the need for a static IP address programmed in Network
Options. To enter a new App Key, press any Select key and enter any combination of 8 digits. Press
COMMAND. The default for this option is blank.
Program > System Reports
The System Reports window allows you to select the reports the panel can send to the central station
receiver. You can also enable keypad door access reports by device address and enable the panel's
Ambush code option.