Specifications
© 2015 Digital Monitoring Products
entered. If 0 (zero) is entered, the panel does not answer the phone when all system areas are armed.
The default is 8 (eight).
Disarmed Answer Rings: Enter the number of times you wish for the panel to allow the phone line to
ring before it answers while any area of the system is disarmed. Any number from 0 to 15 can be
entered. If 0 (zero) is entered, the panel does not answer the phone when all system areas are armed.
The default is 8 (eight).
PC Modem: Allows connection to an XR150/XR350/XR550 Series, XR500 Series, XR2500F, or XR100
Series panel for remote programming at 2400 baud through the panel dialer. Leave this box unchecked
to allow communication through an SCS-105.
Alarm Receiver (XR150/XR350/XR550 Series and XR100/XR500 Version 205 or earlier, and
Version 207 or higher): Select Yes to enable the panel to accept remote commands and
programming from the alarm receiver. If you select No the panel will not accept remote commands and
programming from the alarm receiver.
Service Receiver (XR150/XR350/XR550 Series and XR100/XR500 Version 205 or earlier,
and Version 207 or higher): Select Yes to enable the panel to accept remote commands and
programming from a secondary service receiver other than the alarm receiver. This option must be
Yes to allow programming from a directly connected computer or an Ether-Com. If you select No, the
panel will not accept remote commands and programming from a secondary service receiver. If you
select No and then attempt to connect to the panel using Remote Link, you will see and error message
and will not be allowed to connect.
Network Options
Allow Network Remote: This option displays only if the panel has network capability. Enable to allow
remote programming over the network.
Encrypt Network Remote: Enable to encrypt data sent over the network. Default is disabled.
Network Programming Port (XR150/XR350/XR550 Series and with Network and XR100N/
XR500N Version 206 or higher): Enter the programming port number. The programming port
identifies the port used to communicate messages from the panel. The default Programming Port
setting is 2001.
Cellular Options
Allow Cell Remote: Enable to allow remote programming over a cellular connection. Default is
enabled.
Encrypt Cell Remote: Enable to encrypt data sent over a cellular connection. Default is disabled.