Specifications

© 2015 Digital Monitoring Products
General Options
Remote Key: Enter an alphanumeric code up to 16 characters long that the panel will use as a
password to verify its identity with Remote Link. The panel must give the correct key to Remote Link
before any programming may take place. All panels are shipped from the factory with the remote key
preset as blank.
For security reasons, the Remote Key cannot be viewed from a keypad connected to the panel.
Remote Disarm: Checking the Remote Disarm box allows the panel to be disarmed remotely. Default
is disabled for XR100/XR500 panels. Default is enabled for XR150/XR350/XR550 Series and XT Series
panels.
Dialer Options
Allow Dialer Remote (XR500/XR100 Version 206 only): Enable to allow remote programming over
the phone line. Default is enabled.
Receiver Key Operation:
When enabled, the panel requests the receiver’s key during its first message to the SCS-1R Receiver
and this becomes the alarm receiver key. A receiver key is an alphanumeric code programmed into the
receiver and identifies it to alarm panels. The panel retains this alarm receiver key in memory and
allows remote commands to be accepted over the dialer from the alarm receiver. If an alarm occurs
during a remote connect, the alarm report is immediately sent to the alarm receiver and does not
appear at the remote programming software.
Enabling this option also enables remote commands and programming to be accepted from a secondary
receiver other than the alarm SCS-1R Receiver. The panel requests the service receiver key the first
time it is contacted by another receiver and this becomes the service receiver key. The panel retains
this service receiver key in memory and accepts remote commands from the service receiver. If an
alarm occurs during a remote connect, the panel disconnects from the service receiver and calls the
alarm receiver. Alarm reports are only sent to the alarm receiver.
It is important that the alarm receiver key and the service receiver key programmed into the receiver
at the central station are NOT the same so the panel can determine the difference between receivers.
When disabled, remote commands and programming are not accepted from the SCS-1R Receiver using
digital dialer and all memory of receiver keys is cleared.
Armed Answer Rings: Enter the number of times you wish for the panel to allow the phone line to
ring before it answers while all areas of the system are armed. Any number from 0 to 15 can be