Zone 3 Request to Exit Strike Time: Enter the number of Request to Exit seconds to elapse. Range
is from 5 to 250 seconds. The default is 5 seconds.
Activate Onboard Speaker: Select to enable the on-board piezo speaker for local annunciation.
Disable to turn the piezo off for all operations. This does not affect remote annunciator open collector
(RA) operation. The default is disabled.
Card Options
Card Options: Select DMP to indicate the reader sends a 26-bit DMP data string. Select CUSTOM if
using a non-DMP credential or user code length of 6 to 12 digits. Select ANY to activate the door relay
for the programmed Zone 3 Rex Strike Time when any Wiegand string is received. Default is DMP.
Note: When set to DMP, the 734/734N/734N-WiFi converts 17 bits of the 26-bit data string
into a 5-digit number.
Wiegand Code Length: When using a custom product, enter the total number of bits to be received
in Wiegand code including parity bits. Select a number between 1-255 to equal the number of bits.
Default is 26 bits.
Typically, an access card contains data bits for a site code, a user code, and start/stop/parity bits.
The starting position location and code length must be determined and programmed into the
734/734N/734N-WiFi Module.
Site Code Position: Enter the site code start position in the data string. Enter a number between 0-
255. Default is 1.
Site Code Length: Enter the number of characters the site code contains. Enter a number
between 1-16. Default is 8.
User Code Position: Enter the User Code start bit position. Enter a number between 0-255.
Default is 9.
User Code Length: Enter the number of User Code bits. For 734, when used with a XR150/
XR350/XR550 Series, version 103 or higher, a custom user code can be a number between 16-40. For
all other panels they can then be a number between 16-32. For 734N/734N-WiFi, custom user codes
can only be a number between 1-255. The default is 16.
Site Codes