Specifications
© 2015 Digital Monitoring Products
devices, as well as annunciation of zones (by type) assigned to those area(s). Display Areas default
selects all area numbers. When Display Areas is left defaulted (all areas selected), Menu Display and
Status List items determine whether zone alarms and troubles display at this device, regardless of
area assignment. Also, all system areas may be armed and disarmed from this device.
Note: For an XR150/XR350/XR550 Series and XR100/XR500 Series system set to All/Perimeter
or Home/Sleep/Away operation, Display Areas should be left at factory default settings.
For Home/Sleep/Away with Guest arming systems, the Display Areas selection determines which
system the keypad arms and disarms. With areas 1, 2 or 3 selected, the keypad is assigned to the
Main system. With area 4, 5 or 6 being the first areas selected, the keypad is assigned to the Guest 1
system. With area 7, 8 or 9 being the first areas selected, the keypad is assigned to the Guest 2
system. Keypads can have additional areas assigned for event display.
User Action Allowed
When an area(s) is selected, the following user actions are allowed:
Arming/Disarming of the area(s) selected from the ARM or DISARM menu
Zone Bypass of zones assigned to the area(s) selected
Zone Monitor of zone assigned to the area(s) selected
Shift schedule changes allowed for the area(s) selected
Closing Check Schedule Extend is allowed for the area(s) selected
Door Schedules changes are allowed for devices that have a matching area(s)
as defined in Device Access Areas
Door On/Off Menu operation is allowed for devices that have a matching area(s)
as defined in Device Access Areas
Note: The previous user actions also require the matching area(s) be programmed in User
Profile: Arm/Disarm area(s).
Status Display Allowed
When an area(s) is chosen, the following displays are allowed:
Armed Status of the selected area(s)
ALL SYSTEM ON when all selected area(s) are armed
Zone Alarms and troubles for burglary (NT, DY, EX, A1, A2) type zones assigned to
the selected area(s)
Late to Close status of the selected area(s)
Zone Status (normal/fault) of zones that are assigned to the selected area(s)
Options and Actions Not Affected
The following options are not affected by the Display Areas operation. The User Code authority level
controls access to these items.
Alarm Silence Sensor Reset Menu Outputs On/Off Menu
System Status Menu System Test/Panic Test User Profiles
Forgive Anti-Passback Set System Time and Date Display Events
Service Request Fire Drill
24-hour zones display at keypads based on Status List programming only
Note: A common area and its operations cannot be assigned to a specific keypad
Display Areas example: When Device 1 has Area Display set to 20, 21, and 22, it annunciates troubles