Specifications
© 2015 Digital Monitoring Products
Device Type (XR100/XR500 Series Version 204 or lower): This allows you to specify the type of
device installed at a particular address on the keypad bus.
None: No device is connected to this address.
Standard: Select Standard if you are connecting to any keypad, zone expander, or a
733/734/734N/734N-WiFi Wiegand Interface Module.
Fire: A Model 630F Remote Fire Command Center is connected to this address.
Device Type (XR100, XR500 Series Version 205 or 206):
This allows you to specify the type of device installed at a
particular address on the keypad bus.
None: No device is connected to this address.
Door: The device is an access control device and is either a
keypad or a Wiegand Interface Module.
Fire: The device is a 630F Remote Annunciator.
Keypad: The device is either a keypad or a zone expander
device.
Device Type (XR150/XR350/XR550 Series and XR100/XR500 Series Version 207 or higher):
This allows you to specify the type of device installed at a particular address on the keypad bus.
Door: The device is an access control device and is either a keypad or a Wiegand Interface
Module.
Fire: The device is a 630F Remote Annunciator.
Keypad: The device is a keypad.
Zone Expander: The device is a zone expansion module.
Device Communication Type: For a Device Type of Door, select Keypad Bus to
communicate with a device on the keypad bus or select Network to communicate
with a device using a network connection. Default is Keypad Bus.
For a Device Type of Keypad, select Keypad Bus to communicate with a device on
the keypad bus or select Wireless to communicate with a device that uses a
wireless connection. Default is Keypad Bus.
Serial Number: Enter the eight-digit serial number found on the wireless keypad.
Supervision Time: Select the supervision time required for the wireless device. The device must
check-in at least once during this time or a missing condition is indicated. Zero (0) indicates an
unsupervised wireless keypad. Default is 240 minutes.
Note: When the panel is reset or a receiver is installed or powered down and powered up, or
Remote Link disconnects, the supervision timer restarts for all wireless zones.